47
6. Replace the duct. Place the humidifying tray,
then cover the tray with the humidifying tray
cover as shown in Fig. 5
7. Replace the insulation into the UV lamp lead wire
hole with the wire passed through the cut on the
insulation. See Fig.6
Fig.6
Fig.5
Humidifying tray cover
8. Remove a cap shown in Fig. 7.
By using 4 screws enclosed with this kit,
fix the ballast/glow ass’y as shown in Fig. 7.
Fig.7
Cap
Screw
Ballast
Glow ass’y