-135-
Troubleshooting
Detection of Power failure
Projector provides a protection circuit to prevent the secondary failure when the power failure, fans failure or tempera-
ture failure occurs on the projector. The power failure detection lines "PFAIL_S5V, "FAN_ERR1", etc. are connected
to the power supply lines and fans. When the failure occurs, IC301<SYSTEM CONTROL> receives an error informa-
tion through the ICs<IC5201, IC1801, etc.> and then the operation of power and ballast will be stop by the control
signals, "DC_ON", "BALLAST_AC1", "BALLAST_AC2".
Error information table
IC Pin Signal Name Connection Lines Error Information Failure Area
IC5201
400 PFAIL_DVI S1.2VSI, S3.3VSI HDMI, 3.3/1.2V DVI/HDMI on Main
356 PFAIL_-5V S-5V MAIN, -5V -5V line on Main
358 PFAIL_S5V
S5V, S3.3V_LDVS,
S5V_PW, 9V
MAIN, S5V
S6VNIOS, S6V2, S9.6V, S5V, S3.3V_LDVS,
S5V_PW lines on Main
399 PFAIL_LENS 15V_LENS, 9V_LENS LENS, 15/9V 15V_LENS, 9V LENS lines on Main
398 PFAIL_5V 5V. 3.3V MAIN, 5/3.3V 6V_SW, 5V, 3.3V lines on Main
397 PFAIL_POWER Power(DC), PFC SAFETY-SW, 12V
12V on Power(DC), SW902, SW903, SW904,
PFC1-2 board
310 PFAIL_AD
S3.3V_AD, 1.8V_AD,
1.8VA_AD
A/D, 3.3/1.8V
S6V2, S3.3V_AD, 1.8V_AD, 1.8VA_AD, S6V2
lines on Main
311 PFAIL_MOTHER
S5V, S3.3V, S2.5V,
S1.2VFPGA
MOTHER, 3.3/1.2V
S6V1, S5V, S3.3V, S2.5V, 1.2VFPGA on
Mother or AV
312 PFAIL_NIOS
S3.3V_NIOS,
S2,5V_NIOS,
S1.2V_NIOS, S6VNIOS
NIOS, 3.3/1.2V
S6VNIOS, S3.3V_NIOS, S2.5V_NIOS,
S1.2V_NIOS lines on Main
313 PFAIL_KS
S3.3V_KS, S2.5V_KS,
S1.8V_KS
PWKS, 3.3/1.8V
S6VKS, S3.3V_KS, S2.5V_KS, S1.8V_KS,
S6VKS lines on Main
IC1801 64 PFAIL_FPGA
S3.3V_FPGA,
S3.3V_FPGA_2,
S1.2V_FPGA
FPGA, 3.3/1.2V
S3.3V_FPGA, S3.3V_FPGA_2, S1.2V_FPGA,
6VFPGA lines on Main
IC5201
305 FAN_ERR1 FN905 FAN LOCK FAN1, ERROR Fan lock on FN905, cooling for CW
306 FAN_ERR2
FN904, FN906 FAN
LOCK
FAN2, ERROR
Fan lock on FN904, FN906, cooling for lamps
307 FAN_ERR3
FN903, FN907, FN909
FAN LOCK
FAN3, ERROR
Fan lock on FN903, FN907, FN909, cooling
for power, ballast, optical
308 FAN_ERR4
FN901, FN902 FAN
LOCK
FAN4, ERROR Fan lock on FN901, FN902, exhaust fans
309 FAN_ERR5 FN908 FAN LOCK FAN5, ERROR Fan lock on FN908, cooling for DMD
IC4401
205
FILTER_DET SW1891 FILTER, DET Filter Cartridge Detection, SW1891
198 FILTER_COUNT FILTER_COUNT FILTER, TIME OUT Filter Motor Error
342
343
SHUTTER_POS1
SHUTTER_POS2
SHUTTER_POS1
SHUTTER_POS2
SHUTTER, ERROR
Shutter unit
IC301
179 PRESS_SENS Air Pressure Detection PRESSURE, ERROR Error under the pressure 500mmHg, IC4781
250
33
SDA5_S5V
SCL5_S5V
SLOT1 IIC
SLOT2 IIC
SLOT1
SLOT2
SLOT1, SLOT2
IC401
IC1401
157
280
CW1_INDEX
CW2_INDEX
CW1_INDEX
CW2_INDEX
WHEEL, ERROR
Color Wheel, Formatter board
DDP, ERROR
Formatter board
Power failure detection system

Table of Contents

Other manuals for Sanyo PDG-DHT100L

Related product manuals