-137-
Troubleshooting
Error
Error
Code
Error Infomation
(See Powe Failure Detection Tree)
Error
Code
Error Infomation
(See Powe Failure Detection Tree)
Normal 0 -
Power Failure
1000 HDMI, 3.3/1.2V 1016 FILTER, DET
1001 MAIN, -5V 1017 FILTER, TIME OUT
1002 MAIN, S5V
1018 PRESSURE, ERROR
1003 LENS, 15/9V 1019 SHUTTER, ERROR
1004 MAIN, 5/3.3V 1020 SLOT1
1005 SAFETY-SW, 12V 1021 SLOT2
1006 A/D, 3.3/1.8V 1022 DDP, ERROR
1007 MOTHER, 3.3/1.2V 1023 WHEEL, ERROR
1008 NIOS, 3.3/1.2V
1009 PWKS, 3.3/1.8V
1010 FAN1, ERROR
1011 FAN2, ERROR
1012 FAN3, ERROR
1013 FAN4, ERROR
1014 FAN5, ERROR
1015 FPGA, 3.3/1.2V
Temperature Error
2000
Sensor A detected abnormal temperature (IC8811) (Room)
2001
Sensor A failed temp. mesurement (IC8811)
2100
Sensor B detected abnormal temperature (IC1381) (Optical)
2101
Sensor B failed temp. mesurement (IC1381)
2102
Sensors B-A temperature error
2200 Sensor C detected abnormal temperature (IC8821) (DMD)
2201 Sensor C failed temp. mesurement (IC8821)
2202
Sensors C-A temperature error
Lamp Error
3000 Lamp1 fails on
3001 Lamp1 goes out
3002
Communication Error on Lamp1
3100 Lamp2 fails on
3101 Lamp2 goes out
3102 Communication Error on Lamp2
System Error
4000 FPGASW, CONFIG
4001 FPGAFINE, CONFIG
Filter Error 5000 Filter clogged
Error History Log
This projector provides the error history log function. To
check the logs, you need to enter the service mode and
select Group No. "220" and Item No. "0" to "49". The error
code is displayed on the Data column. The description of
the error code is listed on the table below.
* How to enter the service mode and select the group, item
and data value, see "Service Adjustment Menu Opera-
tion".
Group
No.
Item
No.
Data
(Error Code)
220 0
1
2
3
:
:
49
✻
<- Latest Error
:
:
How to reset the Error History Log
1. Enter the Service Mode, and select Group No. "220" and Item No. "50".
2 The history log will be reset when the Data Value is set to "10". The value automatically returns to "0".
* How to enter the service mode and select the group, item and data value, see "Service Adjustment Menu Operation".