-53-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
248 Filter Scroll Factor (Read only)
0 Filter 1st Cartridge Scroll Factor 1
1st Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
0 - 255 255
1 Filter 1st Cartridge Scroll Factor 2 0 - 255 255
2 Filter 1st Cartridge Scroll Factor 3 0 - 255 255
3 Filter 1st Cartridge Scroll Factor 4 0 - 255 255
4 Filter 1st Cartridge Scroll Factor 5 0 - 255 255
5 Filter 1st Cartridge Scroll Factor 6 0 - 255 255
6 Filter 1st Cartridge Scroll Factor 7 0 - 255 255
7 Filter 1st Cartridge Scroll Factor 8 0 - 255 255
8 Filter 1st Cartridge Scroll Factor 9 0 - 255 255
9 Filter 1st Cartridge Scroll Factor 10 0 - 255 255
10 Filter 2nd Cartridge Scroll Factor 1
2nd Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
0 - 255 255
11 Filter 2nd Cartridge Scroll Factor 2 0 - 255 255
12 Filter 2nd Cartridge Scroll Factor 3 0 - 255 255
13 Filter 2nd Cartridge Scroll Factor 4 0 - 255 255
14 Filter 2nd Cartridge Scroll Factor 5 0 - 255 255
15 Filter 2nd Cartridge Scroll Factor 6 0 - 255 255
16 Filter 2nd Cartridge Scroll Factor 7 0 - 255 255
17 Filter 2nd Cartridge Scroll Factor 8 0 - 255 255
18 Filter 2nd Cartridge Scroll Factor 9 0 - 255 255
19
Filter 2nd Cartridge Scroll Factor 10
0 - 255 255
20 Filter 3rd Cartridge Scroll Factor 1
3rd Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
0 - 255 255
21 Filter 3rd Cartridge Scroll Factor 2 0 - 255 255
22 Filter 3rd Cartridge Scroll Factor 3 0 - 255 255
23 Filter 3rd Cartridge Scroll Factor 4 0 - 255 255
24 Filter 3rd Cartridge Scroll Factor 5 0 - 255 255
25 Filter 3rd Cartridge Scroll Factor 6 0 - 255 255
26 Filter 3rd Cartridge Scroll Factor 7 0 - 255 255
27 Filter 3rd Cartridge Scroll Factor 8 0 - 255 255
28 Filter 3rd Cartridge Scroll Factor 9 0 - 255 255
29
Filter 3rd Cartridge Scroll Factor 10
0 - 255 255
250 Fan Voltage Adjustment
0 Fan A Min Adjust (DAC)
DAC Output for Fan Voltage adj.
Adjust Tolerance between DAC and Fan Volt.
*Lamp Mode: Eco
0-255 65
1 Fan A Max Adjust (DAC) 0-255 220
2 Fan B/C Min Adjust (DAC) 0-255 55
3 Fan B/C Max Adjust (DAC) 0-255 215
4 Fan D/E Min Adjust (DAC) 0-255 85
5 Fan D/E Max Adjust (DAC) 0-255 220
6 Fan F/G Min Adjust (DAC) 0-255 95
7 Fan F/G Max Adjust (DAC) 0-255 220
8 Fan H Min Adjust (DAC) 0-255 65
9 Fan H Max Adjust (DAC) 0-255 220
252 Fan Option
1 Safety Switch Safety Application use 0-8 0
2 Fan Manual Switch Fan Manual SW (0: Auto 1: Manual) 0-1 0
3 Fan A Manual Voltage
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
0-255 100
4 Fan B/C Manual Voltage 0-255 100
5 Fan D/E Manual Voltage 0-255 100
6 Fan F/G Manual Voltage 0-255 100
7 Fan H Manual Voltage 0-255 100
10 Angle Data A Angle Data A (Read only) - -
11 Angle Data B Angle Data B (Read only) - -
12 Press Data Press Data (Read only) - -
L1
L3
L4
L5
L6
L7
L8
112.5°
247.5°
67.5°
292.5°
22.5°
157.5°
202.5°337.5°
L2
Definition of Slant
L1 337.5° ~ 22.5°
L2 22.5° ~ 67.5°
L3 67.5° ~ 112.5°
L4 112.5° ~ 157.5°
L5 157.5° ~ 202.5°
L6 202.5° ~ 247.5°
L7 247.5° ~ 292.5°
L8 292.5° ~ 337.5°
253 Fan Temp Error Setting (Memorized) L1 L2 L3 L4 L5 L6 L7 L8
5 Temp A Warning (Normal) Temp A (Room) to judge the Temp Error at Normal 30-100 45 45 45 45 45 45 45 45
6 Temp B Warning (Normal) Temp B (Optical) to judge the Temp Error at Normal 30-100 75 75 75 75 75 75 75 75
7 Temp C Warning (Normal) Temp C (DMD) to judge the Temp Error at Normal 30-100 70 70 70 70 70 70 70 70
8 Temp B-A Warning (Normal) Temp B - A (Filter Clogged) to judge the Temp Error at Normal 0-100 45 45 45 45 45 45 45 45
9 Temp C-A Warning (Normal) Temp C - A (Filter Clogged) to judge the Temp Error at Normal 0-100 40 40 40 40 40 40 40 40