-51-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
8 HXT_GSEL 0 - 3 0
9 HXT_RDAT1 0 - 255 0
10 HXT_RDAT2 0 - 255 0
11 HXT_RDAT3 0 - 255 0
12 HXT_GDAT1 0 - 255 0
13 HXT_GDAT2 0 - 255 0
14 HXT_GDAT3 0 - 255 0
15 HXT_BDAT1 0 - 255 0
16 HXT_BDAT2 0 - 255 0
17 HXT_BDAT3 0 - 255 0
18 HXT_TH1 0 - 255 0
19 HXT_TH2 0 - 255 0
20 HXT_TH3 0 - 255 0
21 HXT_TH4 0 - 255 0
22 SEL_MODE2 0 - 7 5
109 CXD3540_WEC1
0 WEC_ON 0 - 1 1
200 Option
0 Logo Display Prohibition 0:Menu 1:Forced 0 - 1 0
1 RS232C Baudrate 0: 19200bps 1: 9600bps 0 - 1 0
4 CABLE SW Long Cable 0: Disable 1: Enable 0 - 1 0
5 PW Debug Command Enable
0: Disable (Serial Command Enable)
1: Enable (PW Debug Mode)
0 - 1 0
6 Device Refresh Disable 0: Enable 1: Disable 0 - 1 0
8 PJ-NET Hung up check 0: Enable 1: Disable 0 - 1 0
15 Lens Shift Position Default Setting Reset when the value is set to 10 0 - 10 0
50 Lamp Replacement Display 1:On 0:Off 0 - 1 1
51 Filter Warning Display 1:On 0:Off 0 - 1 1
53 Filter Counter Reset Times Read only 0 - 255 0
54 Factory Default Execute Times Read only 0 - 255 0
55 Motor Operation Stop 0: Enable 1: Disable 0 - 1 0
56 Menu Position Change (X) 0 - 1024 0
57 Menu Position CHange (Y) 0 - 1024 0
58 Lamp Go Out Lamp goes out 0 - 1 0
63 Source Search Enable 0: Disable, 1: Enable 0 - 1 1
70 ADC Device Select for Analog PC 0 = ISL98001, 1 = PW392 AFE 0 - 1 0
71 ADC Device Select for Component 0 = ISL98001, 1 = PW392 AFE 0 - 1 1
72 Component/RGB Auto switch 0: Disable, 1: Enable if set 1, disable items 70 and 71 0 - 1 1
80 Destination Language Set at Shipping 0:English 1:Japanese 0 - 1 0
95 Flicker Mode 1 0: Disable, 1: Enable 0 - 1 0
96 Flicker Mode 2 0 - 15 8
110 Monitor out at Cooling 0: Output at Cooling time, 0: Disable at Cooling 0 - 1 0
111 Image Mute&Still Linkage Enable 0: Disable, 1: Enable
0 -1 1
112
Image Mute&Still Monitor Out Link-
age Enable
0: Disable, 1: Enable
0 -1 1
120 HDMI HPD/EDIO 0: Enable, 1: Disable 0 - 1 1
130 Start Logo Counter 0: 30 sec. 1: 20 sec. 0 - 1 0
140 Offset Addition Setting status
0: Not Excuting
1: Excuting
- 0
141 Offset Addition Setting change Shutter Down Temp. Raising 0 - 10 0
142 Offset Value - 10
143
Offset Addition Setting Excuting
times
0 - 255 0
144
Offset Addition Setting Releasing
times
0 - 255 0
150 Shutter Down Key operation 0:Any Key 1: Shutter Key Only 0 - 1 0
201 Option (Signal)
0 FrameLock Option
Frame Lock Setting 0:Off at PC , 1: Off at AV, 2: All Off, 3:
Normal, 4: Normal
0 - 4 4
1 Dither Enable 0: Disable 1: Enable 0 - 1 1
3 Field Sense Invert Enable 0: Disable, 1: Enable 0 - 1 0
205 Spread Spectrum
0 Enable 0: OFF, 1: ON 0 - 1 1
1 Spread factor Default: 100 0 - 300 200
2 ModulationFrequency Default: 300 1 - 500 150
210 Lamp Control