EasyManua.ls Logo

Sanyo PLC-WM5500 - Error Log Access and Reset

Sanyo PLC-WM5500
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-83-
Troubleshooting
Error Error Code
Error Infomation
(See Power Failure Detection System)
Error Code
Error Infomation
(See Power Failure Detection System)
Normal 0 -
Power Failure
1000 AD, 3.3V 1017 FILTER, 12V
1001 KS, 3.3V 1018 AV, S-6V
1002 KS, 2.5V 1019 FN904, 13V
1003 KS, 1.8V 1020 FN902, 13V
1004 GAMMA, 3.3V 1021 FN901, 13V
1005 GAMMA, 2.5V 1022 FN905, 13V
1006 GAMMA, 1.8V 1023 FN906&7&8, 13V
1007 HDMI, 5V 1024 FN903, 13V
1008 HDMI, 3.3V 1025 FN909&10&11, 13V
1009 HDMI, 1.2V 1026 SWFPGA, 1.2V
1010 MAIN, S3.3V 1027 MAIN, S5V
1011 GAMMA, 15.5V 1028 MAIN, 5V
1012 PJNET, 5V 1029 LAN, 3.3V
1013 LENS, 9V 1030 FILTER, DET
1014 LENS, 15V 1031 MOTOR, TIMEOUT
1015 MAIN, 6V
1016 AUDIO SW, 12V
Temperature Error
2000 Sensor A detects abnormal temperature. (IC1692-ROOM)
2001 Sensor A fails measurement. (IC1692)
2100 Sensor B detects abnormal temperature. (IC1816-LAMP)
2101 Sensor B fails measurement. (IC1816)
2102 Sensors B-A temperature error.
2200 Sensor C detects abnormal temperature. (IC1814-PANEL)
2201 Sensor C fails measurement. (IC1814)
2202 Sensors C-A temperature error.
Lamp Error
3000 Lamp1 fails on
3001 Lamp1 goes out
3002 Communication Error on Lamp1
System Error 4000
FPGASW, CONFIG
Shutter Error 5000
SHUTTER, ERROR
Filter Error 6000 Filter clogged
Error Log
This projector provides the error history log function. To
check the logs, you need to enter the service mode and
select Group No. "220" and Item No. "0" to "49". The error
code is displayed on the Data column. The description of the
error code is listed on the table below.
* How to enter the service mode and select the group, item
and data value, see "Service Adjustment Menu Opera-
tion".
Group
No.
Item
No.
Data
(Error Code)
220 0
1
2
3
:
:
49
✻
<- Latest Error
:
:
How to reset the Error Log
1. Enter the Service Mode, and select Group No. "220" and Item No. "50".
2 The history log will be reset when the Data Value is set to "10". The value automatically returns to "0".
* How to enter the service mode and select the group, item and data value, see "Service Adjustment Menu Operation".