Electrical Adjustment
Grp / No. Item Function Range Initial Note
18 Normal Fan1 Min
Fan Spinning Set at Normal (Min/Max) (0.1V)
0000-9990 70 70 70 70
19 Normal Fan1 Max 0000-9990 138 138 138 138
20 Normal Fan2 Min 0000-9990 60 60 60 60
21 Normal Fan2 Max 0000-9990 138 138 138 138
22 Normal Fan3 Min 0000-9990 35 55 55 35
23 Normal Fan3 Max 0000-9990 35 60 60 35
24 Normal Fan4 Min 0000-9990 60 60 60 60
25 Normal Fan4 Max 0000-9990 138 138 138 138
26 Normal Fan5 Min 0000-9990 70 70 70 70
27 Normal Fan5 Max 0000-9990 100 100 100 100
28 Normal Fan6 Min 0000-9990 55 35 35 60
29 Normal Fan6 Max 0000-9990 55 35 45 60
30 Normal Fan7 Min 0000-9990 56 56 65 56
31 Normal Fan7 Max 0000-9990 98 98 98 98
32 Eco Fan Control Min Temp
Temp Sensor Control Start/End Temp at Eco
20-100 25 26 26 26
33 Eco Fan Control Max Temp 20-100 37 37 35 35
34 Eco Fan1 Min
Fan Spinning Set at Eco (Min/Max) (0.1V)
0000-9990 45 45 45 45
35 Eco Fan1 Max 0000-9990 120 120 120 120
36 Eco Fan2 Min 0000-9990 42 42 42 42
37 Eco Fan2 Max 0000-9990 120 120 120 120
38 Eco Fan3 Min 0000-9990 35 40 40 35
39 Eco Fan3 Max 0000-9990 35 40 40 35
40 Eco Fan4 Min 0000-9990 45 45 45 45
41 Eco Fan4 Max 0000-9990 120 120 120 120
42 Eco Fan5 Min 0000-9990 55 55 55 55
43 Eco Fan5 Max 0000-9990 80 80 80 80
44 Eco Fan6 Min 0000-9990 40 35 35 40
45 Eco Fan6 Max 0000-9990 40 35 35 40
46 Eco Fan7 Min 0000-9990 45 50 55 45
47 Eco Fan7 Max 0000-9990 98 98 98 98
255 Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
0-255 45
1 Fan2 Initial Volt 0-255 45
2 Fan3 Initial Volt 0-255 45
3 Fan4 Initial Volt 0-255 45
4 Fan5 Initial Volt 0-255 65
5 Fan6 Initial Volt 0-255 45
6 Fan7 Initial Volt 0-255 55
8 Cooling Time Coolong Time Setting (x30 sec.) 1: 30 3: 90 15: 450 1-15 3
10 Temp Error Cooling Time
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
1-15 3
11 OnStart Cooling Start Threshold 0-100 38
12 After shutdown cooling Cooling Operation after Shut Down (0: No, 1: Yes) 0-1 1
256 Fan Lamp Voltage Down Setting
0 Lamp Voltage Current Lamp Voltage (1V) (Read only) 0-255 ---
1 Lamp Vol Threshold Threshold Voltage (1V) 30-90 30
2 Fan1 Speed Gain Fan Speed Ad Gain (0.1V) 0-1500 0
3 Fan2 Speed Gain 0-1500 10
4 Fan3 Speed Gain 0-1500 10
5 Fan4 Speed Gain 0-1500 10
257 Fan Setting at Dimmer
0 Dimmer Average Check Period
Dimmer Average Check Period (sec.)
0: 10, 1: 30, 2: 60, 3: 90……10:300
0-10 1
259 Fan Air Pressure Setting
0 Press Source Range Low Pressure Sensor Control Range (AD) 0-1023 661
1 Press Source Range High 0-1023 398
6 Press Fan Add Range High Add value of Fan control for Lamp Fan at Normal 0-5000 10
7 Press Fan Add Range Low 0-5000 30
8 Press Fan Add Range High Add value of Fan control for other fans at Normal 0-5000 20
9 Press Fan Add Range Low 0-5000 40
10 Press Fan Add Range High Add value of Fan control for Lamp Fan at Eco 0-5000 5
11 Press Fan Add Range Low 0-5000 15
12 Press Fan Add Range High Add value of Fan control for other fans at Eco 0-5000 20
13 Press Fan Add Range Low 0-5000 40
17 Temp A Warning Normal Highland Temp A (Room) to judge the Temp Error at Normal/Highland 0 - 100 48