Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
2 B-LCCOM 335 0-511
3 R-LCCOM-Gain 191 0-255
4 G-LCCOM-Gain 191 0-255
5 B-LCCOM-Gain 191 0-255
6 R-LCCOM-Bright 0 0-255
7 G-LCCOM-Bright 0 0-255
8 B-LCCOM-Bright 0 0-255
9 R-LCCOM-Cent 18 0-63
10 G-LCCOM-Cent 18 0-63
11 B-LCCOM-Cent 18 0-63
12 R-ENBX-PW 10 0-127
13 G-ENBX-PW 10 0-127
14 B-ENBX-PW 10 0-127
15 R-DXIN 4 0-255 Link with No.18
16 G-DXIN 4 0-255 Link with No.19
17 B-DXIN 4 0-255 Link with No.20
18 R-CLXIN 4 0-255 Link with No.15
19 G-CLXIN 4 0-255 Link with No.16
20 B-CLXIN 4 0-255 Link with No.17
21 R-ENBX1IN 9 0-255
22 G-ENBX1IN 9 0-255
23 B-ENBX1IN 9 0-255
Group102 : Auto Keystone Setup Value
0 OFFSET 0
-1056 -
1056
1 OFFSET SWITCH
0
0 - 1
2 DEBUG MODE
0
0 - 1
3 SERVICE CALIBRATION
0
0 - 1
4 LOCK COUNT
5
1 - 255
5 DELT VERT RESULT
64
1 - 255
6 ANGLE 1 COUNT
1
1 - 10
7 ANGLE 2 COUNT
5
1 - 10
8 BLIND SECTOR 1
160
0 - 1024
9 BLIND SECTOR 3
32
0 - 1024
10 BLIND SECTOR BIAS
61
0 - 1024
Group 103:Help mode for panle domain
0 Help mode on/off 1 0-1
1 APL threshold value
230
0 - 255
2 Max value
21
0 - 255
3 Value per unit time
3
0 - 50
4 Time per 1step
1
1 - 30
5 Realtime APL
RO
1 - 255
Group
200
Option
0
Logo Prohibition (Forced No
Brand)
Logo Prohibition (0: Menu, 1: Forced,
2: China, 3-9: not used)
0 0 - 2 Effective after AC On
1 RS232C Baudrate Baud Rate 0 0 - 2
0: 19200bps, 1: 9600bps, 2:
115200bps
2 PJLink Enable PJLink 0 0 - 1 0: Disable 1: Enable
3 Shipping Setting 0 0 - 20
Default set when the value is set to
10
4 CABLE SW Long Cable 0 0 - 10 0: Disable, 1: Enable
5
PW Debug Command
Enable
0 0 - 1
0:Disable (Serial Command Eanble)
1: Enable (PW Debug Mode)
6 Device Refresh Disable 0 0 - 1
0:Enable, 1:Disable
No last memory
7 Device Access Disable 0 0 - 1
0:Enable (Normal), 1:Disable
No last memory
20 Projector Time Reset 0 0 - 20
Projector Time is cleared when the
value is set to 10
21
Lamp Warning Time
(NORMAL)
Lamp Life at Normal Mode (Warning
Time at Normal)
500 -
8000
22 Lamp Warning Time (ECO)
Lamp Life at Eco Mode (Warning
Time at Eco)
500 -
8000
23 Lamp Warning Time (HIGH)
Lamp Life at High Mode (Warning
Time at High)
500 -
8000
30 Lamp life test enable
0:Disable 1:Enable, for safety test
only
31 Lmap On time(for life test) For test purpose
32 Lamp Off time(for life test) For test purpose