-42-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco (Lamp)
70 70 72 72 30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 100 100 0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 100 100 0-100
15
Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5 0-100
16
Temp B Warning Offset
(Temp)
5 0-100
17
Temp C Warning Offset
(Temp)
15 0-100
18
Temp B-A Warning Offset
(Temp)
0 0-100
19
Temp C-A Warning Offset
(Temp)
0 0-100
20 Temp A Warning Offset (Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X
minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5 0-100
21
Temp B Warning Offset
(Time)
5 0-100
22
Temp C Warning Offset
(Time)
18 0-100
23
Temp B-A Warning Offset
(Time)
1 0-100
24
Temp C-A Warning Offset
(Time)
1 0-100
25 Factory Mode For factor use 0 0-1
Group
254
Fan Control Range Setting (Temp./Voltage)
Normal
Ceiling
HiLand-
Normal
HiLand-
Ceiling
0 High Fan Control Min Temp
Temp Senser Control Start/End Temp.
at High
45 45 44 44 20-100
1 High Fan Control Max Temp 51 51 44 44 20-100
2 High Fan1 Min
Fan voltage value at High (unit: 0.1V)
100 100 135 135 0-255
3 High Fan1 Max 135 135 135 135 0-255
4 High Fan2 Min 85 85 130 130 0-255
5 High Fan2 Max 130 130 130 130 0-255
6 High Fan3 Min 75 80 80 85 0-255
7 High Fan3 Max 80 85 80 85 0-255
8 High Fan4 Min 9999 9999 -
9 High Fan4 Max 9999 9999 -
10
Normal Fan Control Min
Temp
Temp Senser Control Start/End Tem.
p at Normal
45 45 44 44 20-100
11
Normal Fan Control Max
Temp
51 51 44 44 20-100
12 Normal Fan1 Min
Fan voltage value at Normal (unit:
0.1V)
82 82 125 125 0-255
13 Normal Fan1 Max 125 125 125 125 0-255
14 Normal Fan2 Min 75 75 120 120 0-255
15 Normal Fan2 Max 120 120 120 120 0-255
16 Normal Fan3 Min 70 65 75 70 0-255
17 Normal Fan3 Max 75 70 75 70 0-255
18 Normal Fan4 Min 9999 9999 -
19 Normal Fan4 Max 9999 9999 -
20 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.
p at Eco
44 44 44 44 20-100
21 Eco Fan Control Max Temp 50 50 44 44 20-100
22 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
63 63 115 115 0-255
23 Eco Fan1 Max 115 115 115 115 0-255
24 Eco Fan2 Min 70 70 110 110 0-255
25 Eco Fan2 Max 110 110 110 110 0-255
26 Eco Fan3 Min 55 55 55 55 0-255
27 Eco Fan3 Max 55 55 55 55 0-255
28 Eco Fan4 Min 9999 9999 -
29 Eco Fan4 Max 9999 9999 -
Group
255
Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
70 0-255
1 Fan2 Initial Volt 70 0-255
2 Fan3 Initial Volt 70 0-255
3 Not used 9999 -
4 Fan1 Cooling Speed Fan Voltage at Power Off (0.1V) 130 0-255
5 Fan2 Cooling Speed 130 0-255
6 Fan3
Cooling Speed 130 0-255
7 Not used 9999 -
8 Cooling Time L1
Cooling Time stting at Fan Mode L1 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
2 1-15