-44-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at
Eco (Room)
46 46 30-100
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco (Panel)
62 62 30-100
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco (Lamp)
60 60 30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 0-100
15
Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5 0-100
16
Temp B Warning Offset
(Temp)
15 0-100
17
Temp C Warning Offset
(Temp)
15 0-100
18
Temp B-A Warning Offset
(Temp)
100 0-100
19
Temp C-A Warning Offset
(Temp)
100 0-100
20
Temp A Warning Offset
(Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
15 0-100
21
Temp B Warning Offset
(Time)
30 0-100
22
Temp C Warning Offset
(Time)
30 0-100
23
Temp B-A Warning Offset
(Time)
40 0-100
24
Temp C-A Warning Offset
(Time)
40 0-100
Group
254
Fan Control Range Setting (Temp./Voltage)
Normal Ceiling
0 High Fan Control Min Temp
Temp Senser Control Start/End Temp.
at High
38 38 20-100
1 High Fan Control Max Temp 42 42 20-100
2 High Fan1 Min
Fan voltage value at High (unit: 0.1V)
95 95 0-255
3 High Fan1 Max 135 135 0-255
4 High Fan2 Min 85 85 0-255
5 High Fan2 Max 130 130 0-255
6 High Fan3 Min 75 75 0-255
7 High Fan3 Max 77 77 0-255
8 High Fan4 Min(LAMP1) - - 0-255
9 High Fan4 Max(LAMP1) - - 0-255
10 High Fan5 Min(LAMP1) - - 0-255
11 High Fan4 Max(LAMP1) - - 0-255
12 Normal Fan Control Min Temp
Temp Senser Control Start/End Tem.p
at Normal
38 38 20-100
13
Normal Fan Control Max
Temp
42 42 20-100
14 Normal Fan1 Min
Fan voltage value at Normal (unit:
0.1V)
80 80 0-255
15 Normal Fan1 Max 125 125 0-255
16 Normal Fan2 Min 75 75 0-255
17 Normal Fan2 Max 80 120 0-255
18 Normal Fan3 Min 70 70 0-255
19 Normal Fan3 Max 70 70 0-255
20 Normal Fan4 Min - - 0-255
21 Normal Fan4 Max - - 0-255
22 Normal Fan5 Min - - 0-255
23 Normal Fan5 Max - - 0-255
24 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.p
at Eco
36 36 20-100
25 Eco Fan Control Max Temp 42 42 20-100
26 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
65 65 0-255
27 Eco Fan1 Max 115 115 0-255
28 Eco Fan2 Min 70 70 0-255
29 Eco Fan2 Max 110 110 0-255
30 Eco Fan3 Min 53 53 0-255
31 Eco Fan3 Max 53 53 0-255
32 Eco Fan4 Min(LAMP1) - - 0-255
33 Eco Fan4 Max(LAMP1) - - 0-255
34 Eco Fan5 Min(LAMP1) - - 0-255
35 Eco Fan5 Max(LAMP1) - - 0-255
Group
255
Fan Start/Cooling Setting