- 26 -
5-4
Lamp Ballast Units removal.
B
B
A
Lamp ballast 1-2
units
Ballast1
Ballast2
Holder -D
Grounding Lead
Lamp ballast 3-4
units
Ballast3
Ballast4
D
D
E
Holder -E
Holder -F
F
F
F
Washer
1. Remove screws-C, remove washer and remove the grounding lead. (Lamp ballast 3-4 units. See Fig.5-4)
Fig.5-4
C
Grounding
Lead
Lamp ballast
3-4 unit
Washer
Fig.5-4
Fig.5-4a
Fig.5-4b
Mechanical Disassemblies
2. Remove screw-A, remove washer and remove the grounding lead from the Holder.
(Lamp ballast 1-2 units. See Fig.5-4a)
3. Remove 2 screws-B and remove the Holder-D.
4. Remove the Lamp Ballast Unit1 and Lamp Ballast Unit2.
5. Remove 3 screws-F and remove the Holder-F.
6. Remove 2 screws-D, remove screw-E and remove the Holder-E.
7. Remove the Lamp Ballast Unit3 and Lamp Ballast Unit4.
(See Fig.5-4, 5-4a, 5-4b,)