-44-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
0
Logo Prohibition
Logo Prohibition (0: Menu, 1: Forced) 0 0 - 1 Effective after AC On
1 RS232C Baudrate Baud Rate 0 0 - 2
0: 19200bps, 1: 9600bps,
2: 115200bps
2 PJLink Enable PJLink 1 0 - 1 0: Disable 1: Enable
4 CABLE SW Long Cable 1 0 - 1 0: Disable, 1: Enable
5
PW Debug Command
Enable
0 0 - 1
0:Disable (Serial Command Eanble)
1: Enable (PW Debug Mode)
6 Device Refresh Disable 0 0 - 1
0:Enable, 1:Disable
No last memory
7 Device Access Disable 0 0 - 1
0:Enable (Normal), 1:Disable
No last memory
40
Lamp PWM PresAv
50Hz
80 0-255
41
Lamp PWM PresAv
60Hz
67 0-255
42
Lamp PWM PresUnlock
65 0-255
43
Lamp PWM PresPcA
2 0-255
44
Lamp PWM PresPcB
3 0-255
45
Lamp PWM
PrefHAv50Hz
5000 0-65535
46
Lamp PWM
PrefHAv60Hz
5000 0-65535
47
Lamp PWM PrefHUnlock
5000 0-65535
50
Lamp Replacement
Display
1 0-1
51 Filter Warning Display Filter Warning Display On / Off 1 0-1 1: On, 0: Off
52 Lamp Counter Reset Times Reset Times of Lamp Counter 0 0-255 Read only
53
Filter Counter Reset Times Filter Counter Reset Times 0 0-255
54
Factory Default Execute
Times
Reset times of Fanctory Default 0 0 - 255 Read only
56 Menu Position Move menu (X asis) 0 0 - 1024
57 Menu Position Move menu (Y asis) 0 0 - 1024
59 Source Search Enable
Source Search Enable
(0: Disable 1:Enable)
1 0-1
60 Language Default Setting
Language Default setting
(0: English 1:Japanese)
0 0-1
65
Mute Setting In Freeze status
Mute On/Off in Freeze status 1 0-1 1: On, 0: Off
66 Iris Warning Display Iris Warning Display On/Off 1 0-1 1: On, 0: Off
Group 201 Option (signal)
0 FrameLock Option 1 0 - 1
0: FrameLockOFF at PC signal
1: FrameLockON at PC signal and
47Hz (Vfreq) ~ Panel frequency of
input signal
2 Field Sense Invert Enable 0 0 - 1
Reverse Processing of
FLDINVSetting Value
0: Disable - Used FLDINV Setting
Value
1: Enable - Used Reversed FLDINV
Setting Value
4 Sub Image Enable 1 0 - 1
0:Disable (Service Adjustment
Dsiable, Used all the Center Values
1:Enable (Service Adjustment
Enable)
6 Zoom Accelerator Enable 0 0 - 1
0:Zoom Accelerator OFF,
1:Zoom Accelerator ON
No last memory
7 DZoom Reset by Keystone 0 0 - 1
0:Enable (Normal), 1:Disable (Dzoom
is not cancelled even if Keystone is
cancelled)
No last memory
8 Stability Count Count Value of V-missing 5 0 - 255
9
Sensivity for Signal Lost
(HSYNC)
Only used this value for No Signal
Judgement(Hz)
350 0 - 32767
10
Sensivity for Signal Lost
(VSYNC)
Only used this value for No Signal
Judgement(Line)
3 0 - 255
11 Keystone Filter Center Value Reference Value 16 0 - 30
Group 202 Option (MCI model only)
0 Memory Viewer OSD
Memory Viewer OSD Display (1: Yes,
0: No)
1 0 - 1
1 SIMPLE_CHANNEL_NUM 11 0-11
Group
205
Spread Spetrum