Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
0 Enable 0=Enable, 1=Disable 1 0 - 1
1 Modulation frequency 300 1 - 500
2 Diffusivity 200 0 - 300
Group
210
Lamp Control
0 DIMMER_CTRL_LEVEL1
Luminance Level 1 Data for Dimmer:
Dim Level 1 at the less than the Value
7 0-255
1 DIMMER_CTRL_LEVEL2
Luminance Level 1 Data for Dimmer:
Dim Level 2 at the less than the Value
14 0-255
2 DIMMER_CTRL_LEVEL3
Luminance Level 1 Data for Dimmer:
Dim Level 3 at the less than the Value
21 0-255
3 DIMMER_CTRL_LEVEL4
Luminance Level 1 Data for Dimmer:
Dim Level 4 at the less than the Value
28 0-255
4 DIMMER_CTRL_LEVEL5
Luminance Level 1 Data for Dimmer:
Dim Level 5 at the less than the Value
35 0-255
5 DIMMER_CTRL_LEVEL6
Luminance Level 1 Data for Dimmer:
Dim Level 6 at the less than the Value
42 0-255
6 DIMMER_CTRL_LEVEL7
Luminance Level 1 Data for Dimmer:
Dim Level 7 at the less than the Value
49 0-255
7 DIMMER_CTRL_LEVEL8
Luminance Level 1 Data for Dimmer:
Dim Level 8 at the less than the Value
56 0-255
8 DIMMER_CTRL_LEVEL9
Luminance Level 1 Data for Dimmer:
Dim Level 9 at the less than the Value
63 0-255
9 DIMMER_CTRL_LEVEL10
Luminance Level 10 Data for Dimmer:
Dim Level 10 at the less than the
Value
70 0-255
10 DIMMER_CTRL_LEVEL11
Luminance Level 11 Data for Dimmer:
Dim Level 11 at the less than the
Value
77 0 - 255
11 DIMMER_CTRL_LEVEL12
Luminance Level 12 Data for Dimmer:
Dim Level 12 at the less than the
Value
84 0 - 255
12 DIMMER_CTRL_LEVEL13
Luminance Level 13 Data for Dimmer:
Dim Level 13 at the less than the
Value
91 0 - 255
13 DIMMER_CTRL_LEVEL14
Luminance Level 14 Data for Dimmer:
Dim Level 14 at the less than the
Value
98 0 - 255
14 DIMMER_CTRL_LEVEL15
Luminance Level 15 Data for Dimmer:
Dim Level 15 at the less than the
Value
105 0 - 255
15
DIMMER_AVERAGE_POINT
Luminance Data Avarage Point for
Mimmer
4 1 - 16
16 DIMMER_AVERAGE_DATA
Luminance Data Avarage Value for
Dimmer
- - * Read only
17 DIMMER_LEVEL_AUTO Current Dimmer Leverl - - * Read only
18 DIMMER_LEVEL_NORMAL Normal Dimmer Level 12 0 - 15
19 DIMMER_LEVEL_ECO Eco Dimmer Level 1 0 - 15
20 Lamp check enable 0 0 - 1
0: Lamp
Failure
Detection
OFF (White
50% Back),
1 : ON (Blue
100% Back)
21 VOLTAGE_LEVEL Lamp Voltage -
Unit:
8bit(Raw
Data) *
Read only
22 DIMMER_LEVEL_HIGH Dimmer level High 15 0 - 15
23 Past Calculation System - -
24 New APL System - -
25 Red Average Level - -
26 Green Average Level - -
27 Blue Average Level - -
28 SAT - -
29 Chroma Coefficient - -
30 cSatMin 53 0-255
31 cSatMax 203 0-255
32 wCoeMin 400 0-1000
33 wCoeMax 1000 0-1000
Group
211
General
0 Mode 0 0-3
1 Error Detect Enable 1 0-1
2 Open Position Offset -12 -511-511
3 Speed adjust 1/1 1-1023 (AV/PC)
4 Manual Position Adjust 0 0-1023