-43-
Electrical Adjustment
16-step gray scale 100% full color bar
Black and noisy
image appears
[2] Manual adjustment (Component)
Input mode Video mode (Input 2 -Component)
Input signal 100% color bar signal (480i)
100% color bar signal (480p)
100% color bar signal (720p)
100% color bar signal (1080i)
1. Enter the Service mode.
2
. At first, input the 100% color bar signal (480i).
3.
Adjust the data values listed in the table below as the
100% white part on the screen becomes the most
noisy (darkest).
Group No. Adjustment
0 - 3 Y Gain
4.
Change another input signal and take step 3 again.
When the PC, Video or Component Auto Calibration
fails, take the following manual adjustment instead of
auto calibration.
[1] Manual adjustment (PC)
Input mode Computer mode (Input 1 RGB)
Input signal 16-step gray scale computer signal
1. Enter the Service mode.
2.
Adjust the data values listed in the table below as the
100% white part on the screen becomes the most
noisy (darkest).
Group No. Adjustment
10 - 3 ADC-Green Gain
10 - 4 ADC-Red Gain
10 - 5 ADC-Blue Gain
W Y C G M R B BK
Black and noisy
image appears
[3] Manual adjustment (Video)
Input mode Video mode (Input 3 Video)
Input signal 16-step gray scale composite video
signal
1. Enter the Service mode.
2. Adjust the data values listed in the table below as the
100% white part on the screen becomes the most
noisy (darkest).
Group No. Adjustment
20 - 0 Y Level
PC, Video, Component Manual adjustment
Image example of manual adjustment
for [PC / Video]
Image example of manual adjustment
for [Component]

Table of Contents