A tare value entered manually overwrites a stored tare value (weight value). If you
enter a tare value manually, a tare value (weight value) stored later overwrites the
manually entered value.
Setting: Applic. / TARE.FNC menu item 3.25.2
Restore factory default settings: Applic./Reset menu item 9.1.
Target Checkweighing entails comparing the current weight value to a defined target. You
can enter the value for this target using the keypad, or by saving the weight value
indicated. You can also define upper and lower tolerance limits based on this target.
You can do this by:
Entering absolute values using the keypad or placing the desired amount of
weight on the platform and saving the value
or
by entering each value as a percentage deviation of the target weight
or
by entering each value as an asymmetrical percentage deviation of the target
weight that is selected via the keypad or using the r key
or
by entering a relative weight deviation from the target weight via the keypad.
The value remains valid until deleted by pressing the c key or until overwritten by
a new value. It remains saved after the scale is switched off.
Preparation t Open the APPLIC. / APPLIC.2 / CHECK.WG menu.
Available parameter settings * = Factory setting
MIN.INIT Minimum load for initialization 3.5
1 digit 1 digit 3.5.1*
2 digit 2 digits 3.5.2
5 digit 5 digits 3.5.3
10 digT. 10 digits 3.5.4
20 digT. 20 digits 3.5.5
50 digT. 50 digits 3.5.6
100 diG. 100 digits 3.5.7
200 diG. 200 digits 3.5.8
500 diG. 500 digits 3.5.9
1000 dI. 1000 digits 3.5.10
Aut.strt Automatic start of applications when you switch on
the device with most recently saved application data 3.8
automat Automatic (on) 3.8.1*
manual Manual (off) 3.8.2
TARE.FNC Tare function 3.25
normal Can add a preset tare if tare value is avail-
able; however no tare function possible
3.25.1*
special When a preset tare is entered, the tare
value is deleted; however, tare function
activation is possible 3.25.2
CHECK.RG Checkweighing range 4.2.
30- 170% 30 to 170% 4.2.1*
10-max.l 10% to infinity 4.2.2
Operating Instructions Combics Indicators 73
Operation

Table of Contents

Other manuals for Sartorius combics 1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sartorius combics 1 and is the answer not in the manual?

Sartorius combics 1 Specifications

General IconGeneral
BrandSartorius
Modelcombics 1
CategoryMonitor
LanguageEnglish

Related product manuals