Do you have a question about the Sartorius combics 1 plus and is the answer not in the manual?
General safety advice for using the indicator and preventing damage.
Precautions for safe installation, including cable use and grounding.
Information on IP ratings and how to maintain them for protection.
Guidelines for using the equipment in legal metrology contexts within the EU.
Steps for unpacking the equipment and checking for visible damage.
Guidance on choosing a suitable location and conditioning the indicator.
Instructions for connecting to AC power and the required warm-up time.
Explains the functions of various keys and their behavior during operation.
Describes how to input data for weighing and measurement using the keypad.
Details how to use the digital input port for external control signals.
Instructions on how to open, navigate, and exit the operating menu.
Explains alphanumeric and numeric input methods for menu settings.
Details on how settings are saved and the role of passwords for protection.
Covers zeroing, taring, unit toggling, and ID code entry in basic weighing.
Explains automatic taring, minimum load settings, and automatic printing functions.
Instructions for entering tare values and ID codes using a bar code scanner.
Illustrates the sequence of actions for a basic weighing operation.
Explains the purpose of calibration and adjustment and available features.
Details the steps for performing external calibration with default weights.
Details features like reference weight, automatic updating, and using two instruments.
Explains how to enter reference sample quantity and calculate average weight.
Provides an overview of the operating menu structure, levels, and available functions.
Details the main menu sections (Appl, Fn-key, Setup, Info, Lang) and their functions.
Instructions for assigning a password to protect application and device settings.
Lists and explains parameters for the basic weighing function.
Lists and explains parameters specific to the counting application.
Lists and explains parameters for the neutral measurement application.
Lists and explains parameters for the averaging (animal weighing) application.
Lists and explains parameters for the checkweighing application.
Lists and explains parameters for the classification application.
Lists and explains parameters for the weighing in percent application.
Lists and explains parameters for the net-total formulation application.
Lists and explains parameters for the totalizing application.
Details how to assign functions to the Fn-key.
Explains device parameters and the password setting for security.
Details settings for WP-1, including ambient adaptation, filters, stability, and units.
Covers calibration, adjustment sequences, zero settings, and calibration weights.
Details available weight units and display accuracy settings for WP1.
Details COM1 interface settings and configuration for WP2.
Explains configuration of data protocols like SBI, XBPI, and ADC, including baud rate and parity.
Provides instructions for connecting an analog weighing instrument or load cell to WP1.
Explains the purpose of the service menu and the 'S' indicator.
Lists advanced functions available in service mode, including date, memory, model, and A/D converter settings.
Step-by-step instructions for activating the service mode, including password entry.
Explains the purpose of ADC configuration and important notes on settings.
Details the menu structure and items for configuring the A/D converter.
Covers settings for multi-range instruments and available weight units for ADC configuration.
Explains selecting the calibration unit and saving the ADC configuration.
Explains standard/trade configurations and accuracy class settings.
Details selecting the configuration unit and weighing range for ADC setup.
Outlines the procedure for configuring the A/D converter and saving the settings.
Provides notes on settings and the step-by-step procedure for external linearization.
Lists error codes, their causes, and initial troubleshooting steps.
Details specifications related to metrology, accuracy classes, and scale intervals.
Covers electrical safety, power supply, operating temperature, and emissions/immunity.
Details the process for entering and confirming general and service passwords.