Do you have a question about the Sartorius Cubis MCA224S Series and is the answer not in the manual?
| Maximum Capacity | 220 g |
|---|---|
| Readability | 0.1 mg |
| Repeatability (standard deviation) | 0.1 mg |
| Linearity | ± 0.2 mg |
| Type | Analytical Balance |
| Connectivity | USB, RS232 |
| Power Supply | 50/60 Hz |
| Operating Temperature | 10 °C to 30 °C |
| Calibration | Internal or external |
Describes the device's intended purpose, usage conditions, and risks of improper use.
Specifies the necessary knowledge and qualifications for individuals operating the device.
Details safety rules for the device's electrical components and power supply.
Describes different draft shield configurations and their constituent parts.
Identifies connections and components on the weighing module for different balance types.
Details the components and information displayed during a weighing operation.
Explains the device's guidance system for complex applications and tasks.
Describes how status, warning, and error messages are displayed and managed.
Categorizes and describes buttons for navigation, editing, and core functions.
Covers user profiles, roles, login procedures, and adaptation options.
Details the hierarchical organization of the device's menus and submenus.
Provides step-by-step instructions for navigating the device's user interface.
Outlines criteria for choosing a suitable environment for device installation.
Covers the installation of analytical and flat glass draft shields and associated components.
Details the procedure for safely connecting the device to the mains power supply.
Covers adjusting settings for ambient conditions and operational requirements.
Details the procedure for setting a password for a user profile.
Guides configuration for network printing via independent Wi-Fi or company networks.
Explains the procedure for powering the device on/off and the warm-up time.
Details the process for logging into and out of user profiles on the device.
Explains how to open, close, and define the opening width of the motorized draft shield.
Covers activating applications from QAPP packages and adding them to tasks.
Outlines the necessary steps to prepare the device before each weighing operation.
Provides the procedure for conducting a standard weighing measurement.
Details the automatic internal calibration and adjustment using the isoCAL function.
Describes the procedures for performing internal calibration and adjustment.
Covers saving values with lot and sample IDs for printouts.
Provides instructions for cleaning the device, emphasizing safe cleaning agents.
Details the procedure for installing firmware updates using a USB mass storage device.
Lists common warning messages, their causes, and suggested remedies.
Provides solutions for frequently encountered issues like blank displays or unstable readings.
Presents detailed performance data like scale interval, capacity, and repeatability for models.