agate_en 02/17
OUTDOOR DUAL TECHNOLOGY CURTAIN DETECTOR
AGATE
Firmware version 1.02
SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
tel. +48 58 320 94 00
www.satel.eu
Question and Answer IconNeed help?

Do you have a question about the Satel AGATE and is the answer not in the manual?

Summary

Warning

Features

Description

Active IR anti-mask

Detects attempts to cover or paint the detector lens using infrared radiation reflection.

Supervision features

Signals trouble on voltage drop below 9V or signal path failure, indicated by alarm relay and steady LED.

Remote LED enable;disable

Allows remote control of the LED indicator via a dedicated terminal connected to common ground.

Electronics board

Terminals

Details the function of each terminal for tamper, LED, power, ground, and alarm outputs.

LED Indicators and Control Pins

Explains pins for enabling/disabling LEDs via jumpers or remote control.

Tamper contact

Describes the tamper contact activated by cover removal from the enclosure.

Microwave and PIR Sensors

Identifies the microwave sensor, PIR sensor, and dual element pyrosensor components.

Tricolor LED indication

Explains the LED color indications for alarm, motion detection, and trouble states.

Sensitivity Adjustment Potentiometers

Describes potentiometers for adjusting microwave and PIR sensor sensitivity.

Anti-mask circuit LEDs

Points out the LEDs related to the anti-mask circuit.

Installation

Start-up and walk test

Separate sensor testing

Procedures for testing microwave and PIR sensors individually, detailing LED indications and jumper settings.

Specifications

Satel AGATE Specifications

Power IconPower
supply voltage12 V DC ±15%
standby current consumption21 mA
maximum current consumption25 mA
Detection and Alarm IconDetection and Alarm
microwave frequency24.125 GHz
detectable speed0.2-3 m/s
alarm signaling period2 s
warm-up period45 s
Installation and Environment IconInstallation and Environment
recommended installation height2.4 m
operating temperature range-40 to +55 °C
maximum humidity93±3%
Weight and Dimensions IconWeight and Dimensions
dimensions44 x 105 x 40 mm
weight92 g