30 Installer Manual SATEL
Enclosure dimensions ................................................................................ 114 x 94 x 23.5 mm
Weight...............................................................................................................................141 g
7.6 INT-KLCDK keypad
Supply voltage ................................................................................................... 12 V DC ±15%
Standby current consumption ..........................................................................................30 mA
Maximum current consumption ......................................................................................110 mA
Environmental class according to EN50130-5 .........................................................................II
Operating temperature range................................................................................. -10…+55 °C
Maximum humidity ..........................................................................................................93±3%
Enclosure dimensions ................................................................................. 160 x 132 x 29 mm
Weight...............................................................................................................................317 g
7.7 INT-KLFR keypad
Supply voltage ................................................................................................... 12 V DC ±15%
Standby current consumption ..........................................................................................60 mA
Maximum current consumption ......................................................................................110 mA
Environmental class according to EN50130-5 .........................................................................II
Operating temperature range................................................................................. -10…+55 °C
Maximum humidity ..........................................................................................................93±3%
Enclosure dimensions ................................................................................. 145 x 143 x 25 mm
Weight...............................................................................................................................346 g
8. Manual update history
Date
Firmware
version
Introduced changes
2013-08 1.12
Information on INTEGRA 256 Plus control panel has been added.
Information on the capability to report events via Ethernet using the UDP
protocol has been added (p. 4).
Information on the event log in INTEGRA 64 Plus control panel has been
corrected (p. 4 and p. 28).
Information on the new INT-TSG keypad has been added (p. 5).
Note about INTEGRA 256 Plus control panel and INT-KSG keypad has been
added (p. 6).
Information on the new INT-AV module has been added (pp. 9, 12 and 17).
Note on clock / RAM backup battery has been modified (p. 12).
Note to recommend restoration of factory settings after control panel first
start-up has been added (p. 21).
Information on ACU-250 and INT-RX-S modules has been added.
2013-12 1.12
Information on the capability to report events by means of GPRS using the
UDP protocol has been added (p. 4).
Information on the INT-TSI keypad has been added (p. 5).
Information on the INT-KLFR keypad has been added (p. 5 and 30).
Information on the INT-RS Plus module has been added (p. 6).
Note about INTEGRA 256 Plus control panel and INT-RS Plus module has
been added (s. 6).