38 PERFECTA 64 M SATEL
2. Keep pressing the key until the cursor indicates the REPLACE BATTERY function.
3. Press .
4. After the “SELECT...” message appears, use the or key to find on the list the
wireless keypad in which you want to replace the battery.
5. Press . Tamper alarms from the selected keypad will be blocked for 3 minutes.
During that time you can replace the battery.
6.20 Service access
If the alarm system is to comply with the EN 50131 standard requirements for
Grade 2, the service access should be limited.
The SERVICE ACCESS function allows you to define the rules of access to the system by the
person using the service code (installer/service technician). These rules apply to all methods
of getting access to the alarm system, i.e. by using keypad, PERFECTA SOFT program and
PERFECTA CONTROL application.
Starting the function will display the list of options. To scroll the list, use the and
keys.
Active – if this option is enabled, the installer/service technician has access to the alarm
system i.e.:
– after entering the service code, it is possible to enter the service mode and run some
functions available in the user menu,
– it is possible to configure the alarm system in the PERFECTA SOFT program.
Partition 1 – if this option is enabled, the installer/service technician can operate the partition
1 (arm / disarm it, clear alarm, bypass / unbypass zones) and edit the users (grant them
access to the partition 1). The option is available, if you have access to the partition 1.
Partition 2 – if this option is enabled, the installer/service technician can operate the partition
2 (arm / disarm it, clear alarm, bypass / unbypass zones) and edit the users (grant them
access to the partition 2). The option is available, if you have access to the partition 2.
Partition 3 – if this option is enabled, the installer/service technician can operate the partition
3 (arm / disarm it, clear alarm, bypass / unbypass zones) and edit the users (grant them
access to the partition 3). The option is available, if you have access to the partition 3.
Partition 4 – if this option is enabled, the installer/service technician can operate the partition
4 (arm / disarm it, clear alarm, bypass / unbypass zones) and edit the users (grant them
access to the partition 4). The option is available, if you have access to the partition 4.
If there is no user in the alarm system having the SERVICE ACCESS right, the
installer/service technician has access to the alarm system (also in the PERFECTA
SOFT program and the PERFECTA CONTROL application), can operate the partitions
and edit the users.
6.21 Establishing communication with PERFECTA SOFT via GPRS/LTE
The PERFECTA SOFT function makes it possible to start communication with the PERFECTA
SOFT program via cellular network (data transmission) to allow remote programming of the
control panel. This is one of the methods for establishing communication between the
PERFECTA SOFT program and the alarm control panel. For more information, please refer to
the control panel programming manual.