6 PERFECTA 64 M SATEL
Service technician – the person whose function is to control operability of the installed alarm
system and its components, as well as to eliminate possible problems. These duties can
be fulfilled by the installer or a person assigned by him.
Siren/beacon – a device providing information about alarms or other events in the alarm
system by means of acoustic or optical signaling.
Tamper alarm – reaction of the alarm system to opening the housing of a device which is
part of the alarm system, tearing off the device from the wall, cutting through the alarm
system cables, etc. Actions taken by the alarm system may be similar as in the event of
alarm, however, if the tamper alarm occurs, it is advisable to call in the installer so that he
can make a checkup.
User – a person which can operate the alarm system, using a code or remote control keyfob.
Warning alarm – in some situations, when the alarm criteria are met, the alarm system does
not take up immediately all the actions provided for in the event of alarm. These actions
are postponed, reaction of the system being limited to signaling warning alarm in keypads
or on indoor sirens/beacons. Thus, the user who has made a mistake entering the
protected area (without disarming the system first), has some extra time to disarm the
system. Contact your installer to obtain detailed information on the situations when the
alarm will be preceded by warning alarm.
Zone – 1. a separated portion of the protected area that can supervised by a detector.
A single zone can be a corridor, window or door. 2. the terminals on control
panel/expander electronics board to which you can connect a detector or another device
whose state is to be supervised (panic button, siren tamper contact, power supply output
indicating loss of 230 VAC supply, etc.).
Zone bypassing (inhibiting / isolating) – procedure preventing the alarm from being
triggered by the selected zone when it is in the armed mode. Violations of the zone will be
ignored by the control panel.
Zone violation – a change of the zone status to another, different from that defined for the
normal state (e.g. as a result of motion being sensed by the motion detector, gas being
sensed by the gas detector, etc.).
5. EN 50131 standard for Grade 2 consequences
If the installer has configured the control panel in compliance with the EN 50131 standard
requirements for Grade 2:
1. The user codes should be composed of at least 5 characters.
2. The amount of information provided in the keypads by means of the indicators, display
and sound signaling is limited.
3. The quick arming from keypad (without entering the code) is not available.
4. Arming may be impossible, if one of the situations provided for in the standard occurs
(zone violation, trouble).
How requirements of the standard affect the use of the control panel is described in detail
hereunder.
6. Keypads
SATEL offers the following keypads for the PERFECTA 64 M alarm control panel:
PRF-LCD – hardwired keypad with mechanical keys,
INT-KSG2R – hardwired keypad with touch keys,
INT-TSG2 – hardwired touchscreen keypad,