[Function]
This is a control function for reading data from the EPC code-compatible RFID tag.
[Format]
<IP1> ,b:X;
Where ,
b = Block Number
Block Name Block No
EPC Area 1
TID Area 2
User 3
[Return Status Format]
[STX(02H)] + Data + [ETX(03H)]
Return status list
Item Contents (Binary) No. of bytes
STX(02H) Start code 1 byte
Data Data Depends on tags and blocks
ETX(03H) End code 1 byte
[Coding Example 1]
<A>
<IP1>,b:1;
<Z>
ESC+IP1
Command ESC IP1 Parameter
Hex code <1B>16 <49>16<50>16<31>16 b
Initial value Nil
When power switch is
OFF
The set command is not maintained.
Valid range within item The set parameter becomes invalid.
Valid range
and term of
command
Valid range between
items
The set parameter becomes invalid.
EPC Code Read