3 Printer operation Media sensor calibration
24
3 Printer operation
This chapter provides information about printer operation.
3.1 Media sensor calibration
You will want the printer to work properly before starting your print jobs. To
do this, you need to calibrate the media sensor. WS printers provide
transmissive and reflective sensor calibration. Take the following steps to
use them.
1. Make sure the media is properly loaded, the print module is closed, and
the printers power switch is set to the OFF position.
2. Press and hold the FEED button, and turn on the printer.
3. Both status lights glow solid orange for a few seconds. Next, they turn to
green shortly, and then turn to other colors. Do one of the following to
select the sensor:
If you want to calibrate the transmissive sensor, when LED 1 turns to
green and LED 2 turns to red, release the FEED button immediately.
If you want to calibrate the reflective sensor, when LED 1 turns to green
and LED 2 turns to orange, release the FEED button immediately.
4. Press the FEED button. The media calibration is complete after the
printer feeds 3-4 labels and stops.