9
ASSEMBLY
TOOLS FOR THE MOUNTING OF THE WOODBURNING STOVE
¬ Spirit level ¬ 4 mm Allen key
¬ Cutting nippers ¬ Crosstip screwdriver
¬ Flat head screwdriver
LOOSE PARTS
The following loose parts are located in the stove's combustion chamber:
¬ Oven mitt ¬ Two flue connection pieces (int. and ext. flue pipe)
¬ Gasket for flue connecting piece ¬ Screws for fastening the flue connection piece
¬ Ash container ¬ UK-blocking and screw
¬ Eco energy label
ADDITIONAL ACCESSORIES
¬ Small shaped floor plate in clear or smoke-coloured glass ¬ Large shaped floor plate in clear or smoke-coloured
¬ Heat-storage stones for High Top
glass
DISPOSAL OF PACKAGING
Your Scan stove may come supplied with the following packaging:
Wood packaging
The wood packaging can be reused and after final use can be incinerated as a CO
2
neutral
product or sent for recycling
Foam Send for recycling or waste disposal
Plastic bags Send for recycling or waste disposal
Stretch/plastic film Send for recycling or waste disposal
FRESH AIR INTAKE
In a well-insulated house the air used for the combustion process has to be replaced. This particularly applies to houses with
mechanical ventilation. There are different ways of making sure that air is exchanged. The most important thing is to ensure that
there is a supply of air to the room where the wood stove is located. The external wall vent must be located as close to the wood
stove as possible, and you must be able to close it when you are not using the stove.
National and local building regulations must be followed with regard to connection of a fresh air intake.