Motor Type
Dual or Single Gate
Over-Current Setting
Operation Speed
Deceleration function
Deceleration Speed
Open/Close delay of dual
gate operation
Auto-Close adjustment
Pedestrian Mode function
(45° opening angle)
Pre-Flashing function
LED Display Definition Parameter Table Description
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
F1-1
F1-2
F1-3
F2-1
F2-2
F4-1
F4-2
F5-1
F5-2
F6-1
F6-2
F6-3
F8-0
F8-1
F8-2
F8-3
F8-4
F8-5
F8-6
F8-7
F8-8
F9-1
F9-2
F9-3
F9-4
FA-0
FA-1
FB-0
FB-1
Motor only
Motor with Limit Switch
Motor with Hall sensor
Dual Gate
Single Gate
100% Full speed
80% Full speed
Function ON
Function OFF
70% Full speed
50% Full speed
30% Full speed
Function OFF
3 sec
10 sec
20 sec
40 sec
60 sec
120 sec
180 sec
300 sec
Mode 1
Mode 2
Mode 3
Mode 4
Function OFF
Function ON
Function OFF
Function ON
1. The factory setting is "F1-1".
1. The factory setting is "F2-1".
1. The factory setting is "F4-2".
1. The factory setting is "F5-1".
1. The factory setting is "F6-2".
1. The factory setting is "01".
1.
Auto-close mode activates when the gates move to
the end position or stopped manually. If the
transmitter, push button, or the key-switch is activated
before the auto-close counting, the gate will close
immediately.
2.
The factory setting is "F8-0".
1.
Please see 3.3 photocell adjustment for
more information
2.
The factory setting is "F9-1". For operation
with a photocell in standard function.
1.
When function is on and button 2 on the remote
is pressed, one gate will open partially.
2.
The factory setting is "FA-1".
1.
When function is ON, the light will flash 3
seconds before the gate operates. If OFF, the
light will begin flashing when the motor begins.
2.
The factory setting is "FB-0".
01 2 sec 11 14 sec
02 3 sec 12 16 sec
03 4 sec 13 18 sec
04 5 sec 14 20 sec
05 6 sec 15 22 sec
06 7 sec 16 24 sec
07 8 sec 17 26 sec
08 9 sec 18 28 sec
09 10 sec 19 30 sec
10 12 sec 20 35 sec
01 0.1A 11 1.1A 21 2.1A 31 3.1A 41 4.1A
02 0.2A 12 1.2A 22 2.2A 32 3.2A 42 4.2A
03 0.3A 13 1.3A 23 2.3A 33 3.3A 43 4.3A
04 0.4A 14 1.4A 24 2.4A 34 3.4A 44 4.4A
05 0.5A 15 1.5A 25 2.5A 35 3.5A 45 4.5A
06 0.6A 16 1.6A 26 2.6A 36
07 0.7A 17 1.7A 27 2.7A 37
08 0.8A 18 1.8A 28 2.8A 38
09 0.9A 19 1.9A 29 2.9A 39
10 1A 20 2.0A 30 3.0A 40
1. Factory setting 25.