EasyManua.ls Logo

Schartec P190 Control Box - Photocell Parameter Settings

Schartec P190 Control Box
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LED Display Definition
Parameter
Table
Description
Photocell 1 function
Photocell 2 function
Buzzer function
Latch release function
(electric lock)
Open/Stop/
Close/Stop
function key
Pedestrian
Mode function
key
Reverse option
when closing
Reverse option
when opening
Functions of D
Key terminal
Functions of S
Key terminal
FC
FD
FE
FF
FG
FH
FI
FJ
FK
FL
FC-0
FC-1
FD-0
FD-1
FE-0
FE-1
FF-0
FF-1
FG-1
FG-2
FG-3
FG-4
FH-0
FH-1
FH-2
FH-3
FH-4
Function OFF
Function ON
Function OFF
Function ON
Function OFF
Function ON
Function OFF
Function ON
A Key
B Key
C Key
D Key
Function OFF
A Key
B Key
C Key
D Key
1. The factory setting is "FC-1".
1. The factory setting is "FD-0".
1. The factory setting is "FE-0".
1.
When function is active, gate
moves slightly forward to
unlock the lock.
2.
The factory setting is "FF-0".
1. The factory setting is "FG-1".
1. The factory setting is "FH-2".
1. FI factory setting FI-7.
2. FJ factory setting is "FJ-7".
1. FK factory setting FK-1.
2. FL factory setting is "FL-2".
No reverse
Reverse 2 seconds within 95% of total stroke.
Reverse 2 seconds within 90% of total stroke
Reverse 2 seconds within 85% of total stroke.
Reverse 2 seconds within 80% of total stroke.
Reverse 2 seconds within 75% of total stroke.
Reverse to the end within 95% of total stroke.
Reverse to the end within 90% of total stroke.
Reverse to the end within 85% of total stroke.
Reverse to the end within 80% of total stroke.
Reverse to the end within 75% of total stroke.
Double gates (Open/Stop/Close/Stop)
Single gates (Open/Stop/Close/Stop)
Pedestrian
Open
Stop
Close
No Function
FI/J-0
FI/J-1
FI/J-2
FI/J-3
FI/J-4
FI/J-5
FI/J-6
FI/J-7
FI/J-8
FI/J-9
FI/J-A
FK/L-1
FK/L-2
FK/L-3
FK/L-4
FK/L-5
FK/L-6
FK/L-7