Note when using Hall sensors (F3 Setting in Hall sensor setting):
Only in "F1-3" Hall sensor mode will the system learn the value of the current consumption. Please re-enter menu
F3 after the learning process in conjunction with a Hall sensor.
ATTENTION: Any setting differing from the factory setting (value 25) must be checked, measured, documented
and documented by a competent person in order to rule out the dangers for life and limb as well as damage to
property .
1. F9-1
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
Photocell 1
Not possible to open gate
No effect
Not possible to open gate
No effect
Gate closes
Photocell 2
Not possible to open gate
Reload automatic closing time
Reload automatic closing time
Gate opens
No effect
Position of Gate
When the photocell beam is interrupted
2. F9-2
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
Photocell 1
Not possible to open gate
Gate movement not possible
Reload automatic closing time
Photocell 2
Open not allowed
Reload automatic closing time
Gate opens
No effect
Position of Gate
When the photocell beam is interrupted
3. F9-3
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
Photocell 1
Reload automatic closing time
Photocell 2
Not possible to open gate
Reload automatic closing time
Gate opens
No effect
Position of Gate
When the photocell beam is interrupted
4. F9-4
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
Photocell 1
Close not possible, Open for 2 seconds when auto closing is ON
Photocell 2
Not possible to open gate
Not possible to close gate
Gate opens
No effect
Position of Gate
When the photocell beam is interrupted
3.3 Photocell Parameter Settings
Functions for when 2 photocells are used
Reverse direction open for 2 seconds
Reverse direction close for 2 seconds
Gate opens
Gate opens
Gate opens
No effect
Not possible to open gate
Gate movement not possible
Gate stops
Gate stops
31