Schindler 3100/3300/6300 J 43402603 / 01 164/269
Copyright © 2017 INVENTIO AG
4706
OVERLAY ALL ELEVATORS ARE IN GROUP
Overlay component are all present
C1:A previously reported error OVERLAY ELEVATOR IN GROUP MISSING
is now recovered.
A1:None
Code Telemonitoring Message
5002
RM NO PHYSICAL DATA CONNECTION TO CC
The data connection from the elevator (remote monitoring data communication
device, for example, modem) to the control center hasn't physically established
or was physically interrupted
C1:Connection physically interrupted or bad
A1:Check data connection (for example, phone line)
C2:Data speed negotiation failed (for example, at modem)
A2:Check configuration (for example, country code)
5003
RM DATA LINE TO CC BUSY
The data connection from the elevator (remote monitoring data communication
device, for example, modem) to the control center hasn't physically established
because the line was busy
C1:Control center not able to answer call of elevator (for example, too
busy)
A1:Do nothing. Wait for next calling attempt.
5004
RM NO LOGICAL DATA CONNECTION TO CC
The data connection from the elevator (remote monitoring data communication
device, for example, modem) to the control center hasn't logically established
or was logically interrupted
C1:Authentication failure
A1:Check parameterization of remote monitoring (for example,
password)
5005
RM MAX DATA CONNECTION ATTEMPTS TO CC EXCEEDED
There were several failed attempts (typically 5) from the elevator control to
establish the data connection to the control center. No further attempts are
performed within the next 24 hours. See previous logged errors to get the
reason of the problem.
5006
RM MAX DATA CONNECTION TIME TO CC EXCEEDED
The maximum connection time between the elevator (remote monitoring data
communication device, for example, modem) to the control center has
exceeded. The connection is aborted.
C1:Too slow data transmission due to bad signal connection
A1:Check quality of data connection