7
3c Align magnet to armature.
a. Press magnet to fully engage with armature.
b. Mark bracket location.
3d Remove magnet.
3e Fully attach bracket.
a. Check bracket alignment with marks.
b. Fully tighten two screws in slotted holes.
c. Drill and tap four (4) remaining holes for #10-24 screws.
d. Fully tighten all screws.
3f Reinstall magnet and secure with two screws.
Actual Size (2x)
Loosely install
screws
For Wiring Installation, see page 8.
L Note: Some warming of the device under routine operation is
normal.