MAINTENANCE
30.30.01.00173/04 www.schmalz.com EN | 53
9.3 Service table
Interval
Daily
Weekly
Monthly
Every 6
months
Annual
inspectio
n (UVV)
Vacuum generation
Does the blower make unusual noises when the
operating valve is closed and the load is sealed and
under suction?
X
X
Have the vacuum generator silencers been cleaned?
X
X
If a dust filter is present, has it been cleaned?
X
X
Electrical installation still OK (cable screw unions
secure)?
X
Is the supply hose in good condition (not brittle, not
kinked, no worn sections, i.e. not leaking)?
Does the hose need to be untwisted?
X
X
Vacuum tube lifter Jumbo
Is the filter mat on the operator handle still present
and has it been cleaned?
X
X
Is the lift tube in good condition
(not porous, no worn sections, no holes, i.e. not
leaking)?
X
X
Can the rotary union be moved easily?
X
X
Is the twist grip or control lever responsive?
X
X
Are the operating instructions still available and are
operators familiar with them?
X
X
Check all load-bearing parts (e.g. suspension of the
Jumbo) for deformation, wear, rust or other damage.
X
Are all connections (hose clamps, etc.) secure?
X
Are the type plate and maximum load plate still
attached to the device?
X
Is the handle or operator handle on tight?
X
Is the non-return valve leaking?
X
X
Function
General condition of the vacuum tube lifter JUMBO,
cleanliness
X
X
Is the vacuum tube lifter JUMBO able to lift and lower
easily without a load attached (hovering position
without load)?
X
X
Can the hovering position of the vacuum tube lifter
JUMBOSPRINT with load be easily adjusted (by
turning the adjusting screw on the operator handle)?
X
Has the recommended annual accident prevention
inspection been completed?
(UVV test badge in Germany)
X