Connecting cables with coupling (female) IP67 / IP69, M12, 8-pole - 8 x 0.25 mm² to DIN 47100
Cable length Ordering code
2,5 m 103011415
5,0 m 103007358
10,0 m 103007359
15,0 m 103011414
Connecting cables with coupling (female) IP69K, M12, 8-pole - 8 x 0,21 mm²
Cable length Ordering code
5,0 m 101210560
5,0 m, angled 101210561
10,0 m 103001389
15,0 m 103014823
Connecting cables (PUR) with coupling (female) IP67 / IP69, M12, 5-pole - 5 x 0.34 mm² to EN 60947-5-2
Cable length Ordering code
5.0 m 103010816
10.0 m 103010818
15.0 m 103010820
6 Actuator coding
Safety sensors with standard coding are ready to use upon delivery.
Individually coded safety sensors and actuators will require the following "teach-in" procedure:
1. Energise the safety sensor.
2. Introduce the actuator in the detection range. The teach-in procedure is signalled at the safety sensor, red LED
on, yellow LED flashes (1 Hz).
3. After 10 seconds, brief yellow cyclic flashes (3 Hz) request the switch-off of the operating voltage of the solenoid
interlock. (If the voltage is not switched off within 5 minutes, the safety sensor cancels the "teach-in" procedure
and signals a false actuator by 5 red flashes).
4. Once the operating voltage is switched back on, the actuator must be detected once more in order to activate
the actuator code that has been taught in. In this way, the activated code is definitively saved!
For ordering suffix -I1, the executed allocation of safety switchgear and actuator is irreversible.
For ordering suffix -I2, the "teach-in" procedure for a new actuator can be repeated an unlimited number of times.
When a new actuator is taught, the code, which was applicable until that moment, becomes invalid. Subsequent to
that, an enabling inhibit will be active for ten minutes, thus providing for an increased protection against tampering.
The green LED will flash until the expiration of the time of the enabling inhibit and the detection of the new actuator. In
case of power failure during the lapse of time, the 10-minutes tampering protection time will restart.