Maintenance
01.00|ROTA THWplus |en
37
Maintenance intervals
Lubrication of the grease areas:
Lubrication interval
Strain
every 25 hours
normal / coolant utilization
every 8 hours
high / coolant utilization
after 1200 hours or
as needed
Total cleaning with disassembly of the
chuck, depending on type and degree of
contamination
Technical condition
With the smallest possible actuating pressure (clamping cylinder),
the base jaws should move evenly. This method only provides a
limited indication and does not replace the measurement of the
clamping force.
If the clamping force has dropped too far or if the base jaws and
clamping piston no longer move properly, the chuck has to be dis-
assembled, cleaned, and relubricated.
Only original SCHUNK spare parts may be used.