Fuel
Fuel type Diesel
Standard fuel tank 500 L
High autonomy fuel tank 1770 L
Lubrication
Oil capacity with filter 48 L
Min. Oil pressure 0.7 bar
Nominal oil pressure 6.5 bar
Oil consumption (100 % load) 0,11 L/h
Oil sump capacity 42 L
Type of lubricant Genlub
Cooling
Engine capacity with radiator 60 L
Max coolant temperature 103 °C
Fan power 19 kW
Ventilator air flow 13.5 m
/s
Refrigerant type Gencool
Thermostat 86-96°C
Alternator data
● Compliant with NEMA MG21 standards, UTE NF C51.111,
VDE 0530, BS 4999, IEC 34.1, CSA
● The alternator is protected against short circuits
● Vacuum impregnation, epoxy winding, IP23 protection rating
Type LEROY SOMER LSA472M7
Number of phases 3
Power factor (cos Phi) 0.8
Number of poles 4
Excitation type AREP
Voltage regulator R450
Short-circuit current 3 IN
Number of bearings 1
Coupling Direct
Control unit(s)
TELYS
Standard specifications:
Voltmeter, Ammeter, Frequency meter
Alarms and faults
:
Oil pressure, Water temperature, Start failure, Overspeed,
Alternator min/max, Battery voltage min/max, Emergency
stop
Engine parameters:
Timer, Oil pressure, Water temperature, Fuel level, Engine
speed, Battery voltage
KERYS
Coupling
: pre-programmed coupling mode selector.
Electrical measurements
:
Voltmeter, Ammeter, Frequency meter
Alarms and faults
:
Oil pressure, Water temperature, Start failure, Overspeed,
Alternator min/max, Battery voltage min/max, Emergency
stop
Engine parameters:
Timer, Oil pressure, Water temperature, Fuel level, Engine
speed, Battery voltage
Additional specifications
:Coupling Website,
Troubleshooting, Assistance and maintenance, plotting and
logging, load impact, 8 configurations available, Compliance
with international standards…