EasyManua.ls Logo

SDMO R570U - Technical Specifications

SDMO R570U
299 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.2. Technical specifications
Range / Generating set type RENTAL POWER / R570U
Weights and Dimensions
Dimensions with standard tank
Dimensions l x w x h:
5031 mm x 1560 mm x 2695 mm
Weight:
4870 kg dry weight 5410 kg in operating configuration
Hood:
M228C
Noise level:
85 dB à 1 m (0.70)
75 dB à 7 m (0.70)
Dimensions with high autonomy tank
Dimensions l x w x h:
5083 mm x 1560 mm x 2780 mm
Weight:
5590 kg dry weight 7240 kg in operating configuration
Hood:
M228C-DW
Noise level
:
85 dB à 1 m (0.70)
75 dB à 7 m (0.70))
Output
Voltage* Hz Phase Load factor
Max current (A)
Emergency
Emergency power
1
kW / kVA
Prime power
2
kW / kVA
480/277 V 60 3 0.8 758 504 / 630 458.2 / 572.7
*Available :
380 / 220 V ;
220 / 127 V ;
208 / 120 V.
(1) ESP: Stand-by output available for emergency use under variable charge up to 200hrs per year as per lSO 8528-1, no overload
available under these service conditions.
(2) PRP: Main output available continuously under variable load for an unlimited time period per year as per ISO 8528-1, an overload
of 10% one hour every 12 hours is available, as per ISO3046-1.
Engine data
Manufacturer / model VOLVO TAD1641GE
Type Turbo
Cylinder configuration 6 x L
Cubic capacity 16.12 L
Rotation speed 1800 Tr/min
Max emergency/prime power at nominal speed 565 / 504 kW
Adjustment type Electronique
Fuel consumption
110 % (emergency power) 137.97 L/h
100 % main power 120.73 L/h
75 % main power 88.79 L/h
50 % main power 59.78 L/h
17/297