7. TROUBLESHOOTING
CPG8V Issue 3 13/09/21
Original Language Version
© Jack Sealey Limited
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
BATTERY REMOVAL
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products
containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack
Sealey Ltd’s Batteries Producer Registration Number (BPRN) is BPRN00705.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Condition Possible Cause Corrective Action
Motor fails to run. - Battery needs recharging.
- Faulty wiring to motor.
- Recharge battery.
- Remove battery, disassemble handle and
check wiring for loose connections.
Pressure release valve opens to
discharge grease.
- Blocked line.
- Blocked bearing.
- Blocked grease fitting.
- Check lines, pipe joints and grease
fittings and remove any obstructions.
Grease gun fails to dispense grease. - Grease tube is out of grease.
- Loss of prime.
- Check valve is not functioning.
- Check that the tube contains grease.
- Repeat priming operation.
- Remove check valve, clean and inspect
the valve seat.
Grease gun continues to lose prime. - Air may be trapped in locations throughout the
grease tube ass’y after bulk filling.
- Grease tube follower may be binding.
- Empty grease tube ass’y, refill and repeat
priming operation.
- Replace grease tube ass’y.
Battery fails to charge. - Charger may not have power.
- Battery may be dead.
- Check the mains charger is providing
power.