26
52%
Min Torque:
5
Max torque:
25
Min Max
20% 5 4.80 5.20
60% 15 14.40 15.60
100% 25 24.00 26.00
Min Torque:
Max torque:
60% 0 0.00 0.00
100% 0 0.00 0.00
© Jack Sealey Limited Issue 5 19/05/20
4
This Sealey Declaration of Conformance is issued at the time of manufacture and its validity is open
ended until the torque tool is used for the first time. Unless otherwise stipulated, a period of 12 months,
or 5,000 cycles, whichever occurs first, may be taken as default values for the interval between
calibration checks. This period starts after first use of the torque tool. (BS EN ISO 6789-1:2017,
clause 5.3 refers).
2
Measurement error shall be less than ¼ of the maximum permissible relative deviation of the torque
tool.
Anti-clockwise
(This part 2 to be completed only where applicable)
3
The observed values fall within the maximum permissible deviation (tolerance). For tools with a flexible
head, the result is valid only if the measuring axis is perpendicular to the axis of the tool.
TORQUE TOOL
CALIBRATION CERTIFICATE
1
Testing is in compliance with International Standard procedures, with test equipment calibrated by a
laboratory traceable to International Standards.
Test machine calibration date
Tolerance ± 4 % of Test Load
Tolerance ± 4 % of Test Load
Declaration of Conformance
(in accordance with BS EN ISO 6789-1:2017)
1
Test units: (Nm, lbf.ft, etc)