26°C
52%
Min Torque:
20
Max torque:
120
Min Max
20% 24 23.04 24.96
60% 72 69.12 74.88
100% 120 115.20 124.80
Min Torque:
Max torque:
Min Max
20% 0 0.00 0.00
60% 0 0.00 0.00
100% 0 0.00 0.00
Tool Model Number
Tool Serial Number
Tested by (print name)
Date of test
4
Notes:
© Jack Sealey Limited Issue 5 19/05/20
4
This Sealey Declaration of Conformance is issued at the time of manufacture and its validity is open
ended until the torque tool is used for the first time. Unless otherwise stipulated, a period of 12 months,
or 5,000 cycles, whichever occurs first, may be taken as default values for the interval between
calibration checks. This period starts after first use of the torque tool. (BS EN ISO 6789-1:2017,
clause 5.3 refers).
Nm
Measurement uncertainty
Ambient temperature
2
Measurement error shall be less than ¼ of the maximum permissible relative deviation of the torque
tool.
1
5
3
The observed values fall within the maximum permissible deviation (tolerance). For tools with a flexible
head, the result is valid only if the measuring axis is perpendicular to the axis of the tool.
STW903
1
Testing is in compliance with International Standard procedures, with test equipment calibrated by a
laboratory traceable to International Standards.
1
2
3
4
Average
Test machine type/name
Test
%
Test
Load
Test machine serial No.
Test machine calibration date
Test
Load
Tolerance ± 4 % of Test Load
Test
%
1
2
4
5
Tolerance ± 4 % of Test Load
2
3
Declaration of Conformance
(in accordance with BS EN ISO 6789-1:2017)
1
Measurement error
2
Average
Humidity
Test units: (Nm, lbf.ft, etc)
TORQUE TESTER
1806261
17/07/2019
±1%