What to do if transmitter zone number appears during Transmitter Sniffer mode on Security Link SL150 Security System, but does not clear?
- BBrandon ValenzuelaSep 10, 2025
If the transmitter zone number appears during Transmitter Sniffer mode but does not clear, it could be because the transmitter zone type (ZT) is set to 00 (Not Used); set ZT to a valid active zone type in field,56. It could also be due to the transmitter battery not being installed; install the proper battery. Finally, the 5800 system transmitter may not be enrolled in the system; enroll the unit in field,56.