1.3. Specification
1.3.1. General Specifications
1) Operational Temperature:
0°C to +50°C (+32°F to +122°F) at a relative humidity 75% or less
2) Storage Temperature:
-20°C to +60°C with a relative humidity of 75% less
3) Temperature Coefficient:
0.1 x (Specified Accuracy) per °C for temperature <18°C to >28°C
4) Max. Voltage between any Input and Ground: DC or AC 600Vrms
5) Basic DC Accuracy: 0.3%
6) Band width: 5MHz(2405, 2505), 1MHz(2401, 2800)
7) Meter AC Band width: 20kHz
8) Power Supply: Ni-MH Battery 4.8V (1.2V x 4 cell)
9) Battery Life Time:
4 Hours without Backlight on,
3 Hours with Backlight on.
10) Battery Change Time: About 3 Hours
11) Battery Change:
Class-2 transformer,
Input: 120V AC 60Hz or 240V AC 60Hz
Output: 9V DC 1A
12) Display Type: Super-Twist 132 x 128 pixels
13) Equipment Dimensions:
90 mm (width) x 195 mm (depth) x 40 mm (height)
14) Equipment Weight: About 460g