2. Set the film speed (ISO) and shutter speed (T)
as shown in the paragraph for "Preparing the
Meter for Operation".
3. Press the measuring switch. The
bol on the display starts flashing.
sym-
4. While the symbol is flashing (for about 90 sec.),
fire the flash unit by pressing its test button (Fig.
7).
5. The appropriate F-stop value will be displayed on
the meter. The measured value is indicated in a
dual display by F-stop number with bar symbols
and bar-dot symbol marks (Fig. 8).
6. It the
symbol is not flashing, the
meter cannot accept wireless flash measurement.
Press the measuring switch again to make the
meter ready for measurement.
Note:
(1) If the measuring range is exceeded,
the digital F-stop number is replaced
with either mark of E.u. (and
for
underexposure) or E.o. (and for
overexposure) (Fig. 9).
(2) The display will continue to indicate the
measured value for about 5 minutes after
measurement. After this period of time the
auto-off circuit will operate and turn the
display off.