6.3 Commands
6.3.1 ConfigLfClock
Configures the 32kHz source.
LfClkConfig parameter:
bits 0-1: LF clock selection:
0: Use 32.768kHz RC oscillator.
1: Use 32.768kHz crystal oscillator.
2: Use externally provided 32.768kHz signal on DIO11 pin.
3: RFU.
bit 2: When to release BUSY signal:
0: Wait for Xtal 32k ready.
1: Wait for Xtal 32k to be ready before releasing the BUSY signal.
bits 3-7: RFU.
Table 6-1: ConfigLfClock Command
Byte 0 1 2
Data from Host 0x01 0x16 LfClkConfig
Data to Host Stat1 Stat2 IrqStatus (31:24)