SMD 989 User Manual
Page 87 (105)
TIME
>TIME: 2010/8/12 03:27:48
SOURCE: NTP SERVER
ADDRESS: 10.0.1.23
TIME
TIME: 2010/8/12 03:27:48
SOURCE: MANUAL
>SET DATE: 2010/8/12
SET TIME: 03:27:48
TEMPERATURE
UNIT TEMP: 26.39C
79.50F
FRONT PANEL LOCK
>PASSWORD: _ _ _ _ _ _ _ _
Unit Time
The time and date for the unit can be set manually or
synchronized with an NTP server. The date and time
are used for storing the correct time for alarms and
logs for accurate representation of when the
occurrence took place.
Temperature
The current temperature for the unit can be viewed in
both Centigrade and Fahrenheit.
Front Panel Lock
The front panel can be locked to prevent any
accidental changes from being made. A password is
prompted before the front panel can be locked. Once
locked, the same password is needed to unlock the
front panel.
10 MHz Reference
The 10 MHz reference clock is automatic presence sensing. If an external clock is present and
the system is capable of locking, it will automatically use the external reference. If no external
presence is detected, the internal clock is used. Disabled by default, the external reference clock
alarm can alert a user if the external reference is lost.