7.2.5 Set Frequency of Sensor via SenseCAP Mate App
Set the corresponding frequency band based on the frequency band of the gateway.
Please refer to section 6 for detail.
1) Click the “Setting” and select the platform is “SenseCAP for Helium”.
2) Select the Frequency Plan, if the gateway is US915, set the sensor to US915.
3) Click the “Send” button, send the setting to the sensor for it to take effect.
4) Click the “Home” button, the App will disconnect the Bluetooth connection.
Then, the sensor will reboot.
5) When the device is disconnected from Bluetooth, the LED flashes as a breathing light.
6) After joining the network successfully, LED flashes fast for 2s.