14
Setra Super Count
TM
Operator's Manual
COUNTING WITH ACCURACY ENHANCEMENT
When counting parts that are not uniform in weight, you can periodically update the average piece
weight (APW) and thereby increase the accuracy. Each time the count key is pressed, the scale will
update the APW as long as the additional weight is less than or equal to the previous sample weight.
If the added weight is more than 100% of the previous sample, the APW will not be updated. For
example, if you start with a sample size of 10 pieces then add 10 more and press the count key, the
APW will be recalculated based on a 20 piece sample. The next time you wanted to update the APW
you could add up to 20 pieces. If you added 11 or more to the original 10 piece sample, the APW
would not be updated and would continue to represent the original 10 pieces. To count using this
accuracy enhancement feature, follow the procedure below.
1. Place an empty container on the scale and press the zero key.
2. Press the sample size key. The scale display will say “Add 10 PCs.”
(The sample size requirement can be increased by pressing the sample size key repeatedly.
The predetermined sample sizes are: 10, 25, 50 and 100 pcs. This sequence of predetermined
sample sizes will repeat itself as the sample size key is pressed.)
3. When you reach the desired sample size, place the requested number of pieces in the con-
tainer.
4. Press the count key. Wait for the “OK” symbol, then slowly add pieces until the displayed count
is increased by 100% or less.
5. Press the count key. The scale displays “UPdAtE” and automatically calculates a new average
piece weight based on the larger number of pieces, and is ready to continue counting.
If “UPdAtE” is not displayed, the additional pieces have exceeded 100% of the previous sample
weight and the APW will not be updated.
CAUTION: This accuracy enhancement feature is disabled if the average piece weight has been
scanned in from a bar code or entered via a computer.
REVERSE COUNTING OR KITTING
Using this feature, you can place a container full of pieces on your scale and count the number of
pieces removed. This is especially helpful when kitting (counting out a certain number of pieces to be
packed together). To perform reverse counting or kitting, use the following procedure:
1. Place a container full of pieces you wish to count on the pan.
2. Press the zero key then press the sample size key.
3. The scale display will say “Add 10. PC”. (The sample size requirement can be increased by
pressing the sample size key repeatedly. The predetermined sample sizes are: 10, 25, 50 and
100 pcs. This sequence of predetermined sample sizes will repeat itself as the sample size
key is pressed.)
4. When you have selected the desired sample size, REMOVE the indicated number of pieces
from the container.
5. Press the count key.