Supervisor Setup Super II 45
MACRO STEPS:
NAME FUNCTION PROMPT
ZERO Zeros any weight on the scale Zero the scale by pressing the ZERO key.
TARE Subtracts container weight Place an empty container and press the
TARE key.
TARE WT Allows numeric tare weight entry Enter the tare weight and press the TARE WT
key.
SMPL/CT Determines APW based on sample Add sample and press the SMPL/CT key.
COUNT Switches to the count mode Press the COUNT key to switch to the count mode.
APW Allows numeric APW entry Enter the Average Piece Weight and press the APW key.
ENDCT Prompts to end counting Add pieces until done and press the ENDCT key.
RESTART Returns to beginning of macro Press the RESTART key to start over.
CLEAR Changes from Count to Weight Press the CLEAR key to return to weight.
ID Enters data into ID register Prompts for selected ID field.
RECL DB Recalls record from database Enter ID # and press the RECL DB key to recall the
record from the database.
RESET Clears all and resets macro Press the RESET key to clear all registers and begin
again.
PRINT Prints labels Press the PRINT key. (For selected print format)
NEXT Entry for any non-scale step Do your non-scale related step and press the NEXT key
to continue.
ACCUM Adds display to accumulator Press the ACCUM key to add to the Accumulator register.
SAVE DB Saves the record to database Press the SAVE key to save the record to the database.
ADD CT Adds the count to database Press the ADD CT key to add the count to the database.
SUB CT Subtracts count from database Press the SUB CT key to subtract the scale count from
the database.
BASE Switches active base Prompts to switch to selected base.
SAVE TL Saves a transaction record Press the SAVE TL key to enter a Transaction Log record.
SET PTS Displays set point registers Press the SET PTS key to display the sets point registers.
LOW Enters number in low register Enter the low limit and press the LOW Key.
TARGET Enters number into the target Enter the target limit and press theTARGET key.
HIGH Enters number in high register Enter the high limit and press the HIGH Key.
X UNIT Enters beginning # in sequence Enter the beginning # of the series and press the X UNIT key.
Y UNIT Enters ending # in a sequence Enter the ending # of the series and press the Y UNIT key.
UNITS Switches units for active base Prompts to switch to selected weighing unit.
EXIT Exits macro Press the exit key to end the Macro.

Other manuals for Setra Systems Super II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Setra Systems Super II and is the answer not in the manual?

Setra Systems Super II Specifications

General IconGeneral
BrandSetra Systems
ModelSuper II
CategoryScales
LanguageEnglish

Related product manuals