8
Service
Description of status and operating displays
Operating Instructions – MOVIMOT
®
flexible
202
8.5.2 General LEDs
"F-ERR" LED
LED Meaning
Off
• Device off.
• No MOVISAFE
®
CSB51A safety option available.
Flashing sequence Device identification for safety key ID query.
Green
Steady light
Fault-free operation
Green
Flashing slowly
Error in the operating state "Parameterization"
• No parameterization exists.
• Error in parameterization
• Inconsistent parameterization
• Current parameter set is not consistent with the safety key.
Yellow
Flashing quickly
• Error suppression (muting) active.
• Emergency mode is active.
Yellow
Steady light
Warning: Error connection basic device
Red
Flashing slowly
• Error can be acknowledged.
• Fault outside of the device, cabling system fault
• Reaction to limit value overshoot is active.
Red
Steady light
Critical fault, cannot be acknowledged.
29128668/EN – 12/2019