Instructions
Operating-
102424
Question and Answer IconNeed help?

Do you have a question about the sewerin EX-TEC SR4 and is the answer not in the manual?

Summary

For Your Safety

EX-TEC Product Models and Applications

EX-TEC SR5 & SR4 Applications

Details uses of EX-TEC SR5 and SR4 models for gas detection and monitoring.

EX-TEC SR2 & VARIOTEC 8 Applications

Details uses of EX-TEC SR2 and VARIOTEC 8 models for various detection needs.

EX-TEC Probe Systems

Common Probe Types

Describes probes for gas distribution networks and localization tasks.

Specialized Probe Types

Covers probes for hollow spaces and house service lines.

EX-TEC Measuring Operations

Switching the Detector On

Procedure for turning the EX-TEC detector on.

Operating the Pump

Instructions for operating the detector's internal pump.

Alarm Signals and Volume Control

How to control alarm signals and buzzer volume.

Zero-Point Adjustment Procedure

Procedure for manual zero-point adjustment of the detector.

Workplace Monitoring Function

Details on using the workplace monitoring function.

EX-TEC Charging Procedures

EX-TEC Inspection and Maintenance

EX-TEC Test Set Usage

Details on test sets used for calibration and verification.

EX-TEC Test Gas Information

Lists test gases used for function-testing the detectors.

EX-TEC Function Testing Guide

Step-by-step guide for performing function tests.

EX-TEC Adjustment Guide

EX-TEC Technical Specifications

EX-TEC Technical Data

EX-TEC Error Messages and Troubleshooting

Summary

For Your Safety

EX-TEC Product Models and Applications

EX-TEC SR5 & SR4 Applications

Details uses of EX-TEC SR5 and SR4 models for gas detection and monitoring.

EX-TEC SR2 & VARIOTEC 8 Applications

Details uses of EX-TEC SR2 and VARIOTEC 8 models for various detection needs.

EX-TEC Probe Systems

Common Probe Types

Describes probes for gas distribution networks and localization tasks.

Specialized Probe Types

Covers probes for hollow spaces and house service lines.

EX-TEC Measuring Operations

Switching the Detector On

Procedure for turning the EX-TEC detector on.

Operating the Pump

Instructions for operating the detector's internal pump.

Alarm Signals and Volume Control

How to control alarm signals and buzzer volume.

Zero-Point Adjustment Procedure

Procedure for manual zero-point adjustment of the detector.

Workplace Monitoring Function

Details on using the workplace monitoring function.

EX-TEC Charging Procedures

EX-TEC Inspection and Maintenance

EX-TEC Test Set Usage

Details on test sets used for calibration and verification.

EX-TEC Test Gas Information

Lists test gases used for function-testing the detectors.

EX-TEC Function Testing Guide

Step-by-step guide for performing function tests.

EX-TEC Adjustment Guide

EX-TEC Technical Specifications

EX-TEC Technical Data

EX-TEC Error Messages and Troubleshooting

sewerin EX-TEC SR4 Specifications

General IconGeneral
Alarm Set PointsAdjustable
Operating Temperature-20°C to +50°C
Gases DetectedMethane (CH4), Oxygen (O2), Carbon Monoxide (CO), Hydrogen Sulfide (H2S)
Detection PrincipleCatalytic, Electrochemical
Measurement RangeCH4: 0-100% LEL, H2S: 0-100 ppm
Battery LifeUp to 12 hours
Humidity Range10-95% RH (non-condensing)