- 25 -
5-4-2. F-Function List
Equipment No. setting (ID No.)
00:Normal mode
01: Weight Back up Mode(Zero)
02: Weight Back up Mode(Zero&Tare)
Weighing Data Save Method
00: Manual: Whenever “Print” key input
01: Auto: At every steady states
02: Auto: At the first steady states
04: Manual&Auto: At every steady states
05:Manual&Auto: At the first steady states
06: Manual&Auto: After weighing is finished
00 : kg
01 : g
02 : t
03 : %
01:Slow(1time per 1sec)
~ 09:Fast(60times per 1sec)
00 : Current Weight
01 : Sub-total weight
02 : Grand-total
Under UNPASS/OVERLOAD
state, Weight display
00 : Display
01 : No disply
Buzzer sound (External input
detection)
00 : Buzzer sound
01 : No Buzzer sound
External Input delay time
00 : Continuous Print
01 : Continuous Print(Print “Tare”, “Net weight”)
02 : Single Print
03 : Single Print(Print “Tare”, “Net weight”)