EasyManua.ls Logo

Sewha SI 410 - Weighing mode 5. - Random Packer mode

Sewha SI 410
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 36 -
Weighing mode 5. Random Packer mode (500-05)
Time
Time
Contents
t1
Finish Relay Output Delay Time (Function 510)
When Function 102-3 or 102-6, save the date after t1 time.
t2
Finish Relay Output Time (Function 520)
Relay output
Relay
Condition
Relay
Condition
OUT 1
Start On (ON)
Current weight SP1 (OFF)
OUT 4
Start On (ON)
Current weight SP4 (OFF)
OUT 2
Start On (ON)
Current weight (OFF)
OUT 5
After SP4
After t1 set time
During t2 set time (ON)
OUT 3
Start On (ON)
Current weight SP3 (OFF)
OUT 6
Within near zero range
(Function HF29) (ON)
Drib control : After weighing is finished, if the weight is changed during t1, it will adjust
weighing finished weight by controlling drip gate. (Function 250-01)

Related product manuals