64
A: Misfeed in the paper feed area
1
Gently remove the misfed paper from the paper feed area as
shown in the illustration. When the misfeed ( ) indicator
blinks, and the misfed paper is not seen from the paper feed
area, pull out the paper tray and remove the misfed paper. If the
paper cannot be removed, proceed to "B: Misfeed in the fusing
area".
2
Close the side cover by pressing the round projections near
the side cover open button. The misfeed ( ) indicator will go
out and the start ( ) indicator will light up.
B: Misfeed in the fusing area
1
Lower the fusing unit release
lever.
The fusing unit is hot. Do not touch the fusing unit when
removing misfed paper. Doing so may cause a burn or other
injury.
Do not touch the surface of the drum (green portion) of the
drum cartridge when removing the misfed paper. Doing so
may damage the drum and cause smudges on copies.
If the paper has been fed through the multi-bypass tray, do
not remove the misfed paper through the multi-bypass tray.
Toner on the paper may stain the paper transport area,
resulting in smudges on copies.
Fusing unit release lever
AL-1215_1530-1551CS.book 64 ペー 002年8月7日 水曜日 午前9時34分

Table of Contents

Other manuals for Sharp AL-1215

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp AL-1215 and is the answer not in the manual?

Sharp AL-1215 Specifications

General IconGeneral
BrandSharp
ModelAL-1215
CategoryCopier
LanguageEnglish

Related product manuals